Chapter II
Portable digital multimeter 33
Number of counts : 50 000 (or 5 000, refer to §. 3.4.)
Range selection : automatic or manual for the 500 µA, 5 mA, 50 mA, 500 mA ranges
Additional error according to crest factor : 0.2 % for a crest factor of 2 to 3
0.5 % for a crest factor of 3 to 6
(Specification given full scale for a squarewave signal pulse 200 µs wide)
Additional error in I
AC+DC with a direct current at input : 1 %
5.5. Resistance / Continuity
Ranges Accuracy
Measurement
current
Protection
Resolut
ion
500 Ω /
0.07% R + 5 D
1 mA
10 mΩ
5 kΩ
100 µA
100 mΩ
50 kΩ
10 µA
1 Ω
500 kΩ
0.07% R + 2 D
1 µA
10 Ω
5 MΩ∗∗
0.3% R + 2 D 100 nA
100 Ω
50 MΩ∗∗
1% R + 2 D 50 nA
600 V
RMS
1 kΩ
Overload protection can be reset automatically.
∗∗ It is highly recommended to use very short and shielded test leads for measurements in this
range (> 1 MΩ).
Number of counts : 50 000 (or 5 000, refer to §. 3.4.)
Range selection : automatic or manual (fixed in continuity mode)
Maximum open circuit voltage : 7 V
Detection threshold in continuity mode : 10 Ω to 20 Ω
Response time in continuity mode : 1 ms
5.6. Capacitance
)
Note Discharge all condensers before taking measurements.
Ranges Accuracy
Measurement
current
Max.
measurement
time
Protection
Resolution
50 nF∗∗
100 nA 10 pF
500 nF 1 µA 100 pF
5 µF 10 µA 1 nF
50 µF 100 µA
0.5 s
10 nF
500 µF 1.5 s 100 nF
5000 µF 1 µF
50 mF
1% R + 2 D
1 mA
3 s/mF
600 V
RMS
10 µF
Overload protection can be reset automatically.
∗∗ It is highly recommended to use very short and shielded test leads for measurements in this
range.
Number of counts : 5 000
Range selection : automatic or manual
Maximum open circuit voltage : 7 V
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrix MX 59HD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrix MX 59HD in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrix MX 59HD

Metrix MX 59HD User Manual - German - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info