32 Portable digital multimeter
Curve showing typical measurement error (5 V, 50 V, 500 V ranges)
1000 pts
1 kHz
10 kHz
100 kHz
Vin = 100 % F.S.
Vin = 50 % F.S.
Vin = 15 % F.S.
50000 pts
25000 pts
7500 pts
2500 pts
1%
5%
10%
2%
Vin = 5 % F.S.
5.3.
DC current
Selector
switch pos. Ranges Accuracy
Max volt.
drop Protection
Fuses
Resolution
500 µA 0.2%R + 5 D 10 nA
5 mA 0.2%R + 2 D 100 nA
50 mA 0.05%R+ 2 D
700 mV
1 µA
µA mA
500 mA 0.2%R + 2 D 1.5 V
F1 + F2
10 µA
10 A∗∗ 10 A 0.5%R + 5 D 500 mV
600 V
RMS
F2 1 mA
refer to fuse specifications, §. 6.1.1.
∗∗ acceptance 20 A overload during 30 s. max, observing a 5 min break at least between two
measurements
Number of counts : 50 000 (or 5 000, refer to §. 3.4)
Range selection : automatic or manual for the 500 µA, 5 mA, 50 mA, 500 mA ranges
Additional error in Pk +/- mode for a pulse width of 1 ms : 1% R ± 50 D
For measurements performed on alternative signals, the selected range must tally with the max.
value of the signal peak.
5.4. AC currents (AC and AC+DC)
Accuracy
40 Hz to
5 kHz
5 to 10 kHz 10 to 30 kHz
Ranges
5 % to 100 % of range
Protection
Fuses
Resol.
Max.
crest
500 µA
0,75 % R
+ 30 D
1,5 % typ. 4 % typ. 10 nA 1 mA
5 mA 1,5 % typ. 4 % typ. 100 nA 10 mA
50 mA
0,6 % R
+ 30 D
1,5 % typ. 4 % typ. 1 µA 100 mA
500 mA
0,7 % R
+ 30 D
1,5 % typ. 4 % typ.
F1 + F2
10 µA 1 A
10 A∗∗
1%R+30D
Æ 2 kHz
1,5 % typ. ////////////
600 V
RMS
F2 1 mA 30 A
refer to fuse specifications, §. 6.1.1.
∗∗ acceptance 20 A overload during 30 s. max, observing a 5 min break at least between 2
measurements
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrix MX 59HD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrix MX 59HD in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrix MX 59HD

Metrix MX 59HD User Manual - German - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info