Chapter II
26 Portable digital multimeters
5. TECHNICAL SPECIFICATIONS
5.1. General
Only the values assigned tolerances or given limits are guaranteed values. Values
without tolerances are given for information only, without guarantee (standard NFC
42670). The measurement errors must be considered in an environment of reference
temperature (refer to § 5.2.10).
It is essential that all measuring instruments are regularly calibrated.
5.2. Characteristics
Accuracy is ± [% reading (R) + number of digits (D)].
{Accuracy : ‘’n % R + n D’’ means ‘’n % of the reading + n digits’’ }
5.2.1. DC voltages
Selector switch
position
Ranges
Accuracy
Input impedance
Protection
(∗)
Resolution
ADP
DC
500 mV
DC
11 M
600 V
RMS
0.1 mV
DC
5 V
DC
11 M
1 mV
DC
50 V
DC
10 mV
DC
500 V
DC
100 mV
DC
V
DC
600 V
DC
(∗∗)
0.3 % R + 2 D
10 M
750 Vrms
± 1100 V
DC
1 V
DC
(∗) Acceptance permanent max. voltage
(∗∗) The range can be exceeded by up to 1000 V
DC
or 750 Vrms with the same accuracy as with
the 600 V range. This multimetre can not be used on power distribution networks with a nominal
voltage higher than 600 Vrms.
Number of points : 5000
Range selection : automatic or manual for the 5 V, 50 V, 500 V, 1000 V ranges
Common mode rejection (500 mV range) : at 50 and 60 Hz, better than 120 dB
Serial mode rejection : at 50 and 60 Hz, better than 60 dB, in manual mode
Intermittent signal sounds and « OL » on the display in case of range overpassing.
5.2.2. AC voltages (AC and AC+DC)
Selector switch
position
Ranges
Accuracy
40 Hz to 1 kHz
Input
impedance
Protection
(∗)
Resolution
5 V
AC+DC
1 mV
AC
50 V
AC+DC
10 mV
AC
500 V
AC+DC
100 mV
AC
V
LOW Z
600 V
AC+DC
1.5 % R + 2 D
500 k
600 V
RMS
1 V
AC
ADP
AC+DC
500 mV
AC+DC
1.5 % R + 3 D
11 M // 100 pF
600 V
RMS
0.1 mV
AC+DC
5 V
AC+DC
11 M // 100 pF
1 mV
AC+DC
50 V
AC+DC
10 mV
AC+DC
500 V
AC+DC
100 mV
AC+DC
V
AC+DC
600 V
AC+DC
(∗∗)
1.5 % R + 2 D
10 M // 100 pF
750 Vrms
± 1100 V
DC
1 V
AC+DC
(∗) Acceptance permanent max. voltage
(∗∗) The range can be exceeded by up to 1000 V
DC
or 750 Vrms with the same accuracy as with
the 600 V range. This multimetre can not be used on power distribution networks with a nominal
voltage higher than 600 Vrms.
Specifications applicable from 5 to 100% of range for a sinusoidal signal in band 40 Hz to 1 kHz.
Number of points : 5000
Range selection : automatic or manual for the 5 V, 50 V, 500 V, 600 V, 750 V ranges
Common mode rejection : at 50 and 60 Hz, better than 60 dB
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrix MX 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrix MX 24 in the language / languages: English as an attachment in your email.

The manual is 0,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrix MX 24

Metrix MX 24 User Manual - German - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info