Chapter II
Portable digital multimeters 25
4.1.3. 10 ADC / AAC+DC Position (except MX 23)
4.2. MIN / MAX key (except MX 23)
If you press this key (long press), you access the surveillance mode (or coming out), in
which minimum (MIN), maximum (MAX) and sliding average (AVG) values of the current
measurement are stored (capture time 500 ms). The signs MIN MAX AVG appear on
the display.
You can look up each of these values by repeatedly short pressing the same key.
The symbols MIN, MAX or AVG flicker with the selected value.
The three MIN, MAX, AVG values are stored in memory and can be read after quitting
the surveillance mode.
When you access the surveillance mode again, all previous values stored are cleared.
This key also desactivates the auto power-off, if it is pressed when switching on
P_OFF »).
4.3. MEM / AUTO MEM key
Short press (MEM) : fixes the display on the current value. A second short press returns
the multimeter to normal mode. The MEM sign appears on the
display.
The MEM mode is avaible on all measurement.
Long press (AUTO MEM) : accesses or quits the “autostore” mode.
The MEM sign blinks on the display.
Affected ranges : VLOW Z, VAC+DC, VDC, ADPDC, ADPAC+DC
Autostore
Set the probes on the point to be measured. An audio signal indicates whether the
measurement is stable. When you remove the probes, a second audible signal indicates
that this stable value displayed has been stored.
The bargraph remains active during the "autostore” and display MEM mode.
Pressing this key when switching on the instrument enables the selection of a rejection of
50 or 60 Hz. The selection is reversed from the last configuration. It is displayed for
2 secs. and remains backed up in non-volatile memory.
4.4. key (except MX 23)
Activates/deactivates back lighting of the display unit.
10 AAC+DC
AC+DC current measurement (TRMS)
(Range 10 AAC+DC)
10 ADC
DC current measurement
(Range 10 ADC)
AC+DC key
AC+DC key
The AC+DC sign
appears on the display.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrix MX 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrix MX 24 in the language / languages: English as an attachment in your email.

The manual is 0,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrix MX 24

Metrix MX 24 User Manual - German - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info