MI 3109 EurotestPV Lite Data handling
60
6.5.4 Renaming installation structure elements (upload from PC)
Default installation structure elements are “Object”, “Inverter”, “String” and ‘’Panel’’.
In the PCSW package Eurolink-PRO default names can be changed with customized
names that corresponds the installation under test. Refer to PCSW Eurolink-PRO
HELP for information how to upload customized installation names to the instrument.
Figure 6.12: Example of menu with customized PV installation structure names
6.5.5 Renaming installation structure elements with serial barcode
reader or RFID reader
Default installation structure elements are “Object”, “Inverter”, “String” and “Panel”.
When the instrument is in the Save results menu location ID can be scanned from a
barcode label with the barcode reader or can be read from a RFID tag with the RFID
reader.
Figure 6.13: Connection of the barcode reader and RFID reader
How to change the name of memory location
Connect the barcode reader or RFID reader to the instrument.
Make sure that RS232 is selected in Communication menu.
In Save menu select memory location to be renamed.
A
new location name (scanned from a barcode label or a RFID tag) will be
accepted by the instrument. A successful receive of a barcode or RFID tag is
confirmed by two short confirmation beeps.
Note:
Use only barcode readers and RFID readers delivered by Metrel or authorized
distributor.
60


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI 3109 - Eurotest PV Lite at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI 3109 - Eurotest PV Lite in the language / languages: English as an attachment in your email.

The manual is 1.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI 3109 - Eurotest PV Lite

Metrel MI 3109 - Eurotest PV Lite Quick start guide - Dutch - 68 pages

Metrel MI 3109 - Eurotest PV Lite User Manual - Dutch - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info