MI 3108 EurotestPV Instrument operation
33
ISO PV
No limit
Utest = 500 V
ENV.
Measured
I/V
Measured
INVERTER
AC/ DC
Note:
Initial settings (reset of the instrument) can be recalled also if the TAB key is
pressed while the instrument is switched on.
4.4.9 Clamp Settings
In Clamp settings menu the C1 and C2/P
measuring inputs can be configured.
Figure 4.17: Configuration of current clamp
measuring inputs
Parameters to be set:
Model
Model of current clamp [A1018, A1019, A1391].
Range
Measuring range of current clamp [20 A, 200 A], [40 A, 300 A].
Selection of measuring parameters
Keys
UP / DOWN
Selects appropriate option.
TEST
Enables changing data of selected parameter.
MEM
Saves settings.
ESC
Exits back to clamp settings menu.
Function selector
Exits back to main menu without changes.
Changing data of selected parameter
Keys
UP / DOWN
Sets parameter.
TEST
Confirms set data.
ESC
Disable changing data of selected parameter.
Function selector
Exits back to main menu without changes.
Note:
Measuring range of the instrument must be considered. Measurement range of
current clamp can be higher than of the instrument.
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI 3108 - Eurotest PV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI 3108 - Eurotest PV in the language / languages: English as an attachment in your email.

The manual is 3.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI 3108 - Eurotest PV

Metrel MI 3108 - Eurotest PV User Manual - German - 136 pages

Metrel MI 3108 - Eurotest PV User Manual - Dutch - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info