MI 2092 Power Harmonics Analyser Section VI Theory of operation
55
5. Power breaks recording
If data logging is in progress, the start of every OFF state of the instrument is treated as
a Power Break. This OFF state occurs either if the instrument is switched OFF (using
the rotary switch) or if it lose its power supply.
For each Power Break, the instrument logs the date & time of both the beginning and
end of the power break, and the cause of the power break (manual or loss of supply).
Note: The battery must be in the instrument otherwise its power supply drops
to fast and it can not records Power Break.
6. Memory usage
The non-volatile memory in the Instrument can be used in one of two ways:
Linear mode
In linear mode recording, the Instrument stores data in memory until full and then stops
recording. Thus the oldest data is always preserved irrespective of the amount of
recordable data.
Roll-over mode
When recording in roll-over mode, the Instrument will over-write old data when
memory is filled. Thus, the latest data is always preserved irrespective of the amount of
data recorded, with the older data being possibly lost.
Data logging capacity in linear mode depends on the number of channels selected for
recording, the type of data recorded, the IP and the number of voltages anomalies
detected. It is automatically calculated by the PC software when selecting channels for
logging and is given by the following equation:
Maximum number of records in Periodic Analysis (Rn
max
) is given by:
Rn
NN
R
Statano
len
max
()**
=
-
-
20321024164
Where:
R
len
Record length RXY
len
=
+
+
12612**
N
stat
N° of channels selected for Statistical Analysis
(All being selected for Periodic Analysis, but excluding harmonics).
N
ano
N° of voltage anomalies which occurred while recording.
X N° of channels selected excluding power channels (±P
x
, ±Q
x
, ±P
tot
, ±Q
tot
, ±S
tot
).
Y Power channels
Note: Estimating Voltage Anomalies:
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI 2092 Power Harmonics Analyser at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI 2092 Power Harmonics Analyser in the language / languages: English as an attachment in your email.

The manual is 1,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI 2092 Power Harmonics Analyser

Metrel MI 2092 Power Harmonics Analyser User Manual - Dutch - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info