ENGLISH
C Foot-operated remote control unit
for stepless welding current regula-
tion.
1) with 5 m leads, plastic shell
2) with 5 m leads, aluminium shell
3) with 10 m leads, aluminium
shell
D Hand-operated remote control unit
for stepless welding current regula-
tion.
1) with 5 m leads
2) with 10 m leads
E Welding return cable, 25 mm
2
, 3 m
F Welding cable, 16 mm
2
, 3 m
G Welding visor
1) helmet
2) automatic screen
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Welding machines in need of repair can
be sent to the service centre of your
country. Refer to spare parts list for
address.
Please attach a description of the fault to
the power tool.
The machine's packaging can be 100 %
recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and rubber materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
In case of faults, error messages are dis-
played on the display to help identify the
source of the error.
Simultaneously the Fault LED is perma-
nently lit.
E02
Excess transformer temperature.
The Excess temperature LED is lit.
DO NOT switch machine OFF,
in order for the fan to cool the
machine down faster.
If the temperature has fallen off to
normal levels, the display will show
the welding current again.
You may now continue welding.
E03
The lead to the transformer's tempera-
ture sensor may be broken.
E04
Possible short in the transformer's tem-
perature sensor lead.
E06
The machine's control has detected a
supply voltage of more than 20% below
the rated voltage.
To avoid excess primary currents the
machine shuts down.
3
Note:
This error message must be
acknowledged.
Turn the machine OFF for 5 sec-
onds, then ON again.
If the error message appears again, turn
OFF and contact a qualified electrician!
E12
The arc did not start within 20 sec after
pressing the torch button.
The machine shuts down.
Release torch button.
The message is cleared, the
machine is ready to operate again.
E14
Excess temperature of the primary sec-
tion.
E15
The lead to the primary section's temper-
ature sensor may be broken.
E16
Possible short in the primary section's
temperature sensor lead.
E17
Excess temperature of the secondary
section.
E18
The lead to the secondary section's tem-
perature sensor may be broken.
E19
Possible short in the secondary section's
temperature sensor lead.
8. Repairs
9. Environmental Protection
10. Faults
11. Trouble Shooting
Brittle or porous weld seam
Gas valve
closed?
Open gas valve.
Gas cylinder
empty?
Replace.
Unsuitable shield-
ing gas?
Use a suitable
shielding gas.
Gas line connec-
tion not tight?
Check connec-
tions.
Pressure regula-
tor faulty?
Check pressure
regulator.
Gas shroud on
torch or torch
leads blocked?
Clean gas shroud.
Air draft at weld-
ing spot?
Screen off weld-
ing spot or
increase gas flow
rate.
Workpiece not
clean?
Remove rust,
grease or paint
coating.
Steady gas flow
Solenoid valve
faulty or dirty?
Have solenoid
valve checked by
a qualified electri-
cian.
No welding current
Welding return
cable making
poor contact?
Check welding
return cable for
proper contact.
Control PCB
faulty?
Contact
service centre.
No function of machine
Supply circuit fuse
blown or cut-out?
Replace or turn
ON again.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo WIG 170 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo WIG 170 DC in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 1,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info