4.5 Safety Warnings Specific for Sanding
Operations:
a) Do not use excessively oversized sanding
disc paper. Follow manufacturer's recommen-
dations when selecting sanding paper. Larger
sanding paper extending beyond the sanding pad
presents a laceration hazard and may cause snag-
ging, tearing of the disc or kickback.
4.6 Safety Warnings Specific for Wire Brush-
ing Operations:
a) Be aware that wire bristles are thrown by the
brush even during ordinary operation. Do not
overstress the wires by applying excessive
load to the brush. The wire bristles can easily
penetrate light clothing and/or skin.
b) If the use of a guard is recommended for wire
brushing, do not allow any interference of the
wire wheel or brush with the guard. Wire wheel
or brush may expand in diameter due to work load
and centrifugal forces.
4.7 Additional Safety Instructions
WARNING – Always wear protective
goggles.
Use elastic cushioning layers if they have been
supplied with the abrasive and if required.
Observe the specifications of the tool or accessory
manufacturer! Protect the discs from grease or
impacts!
Grinding discs must be stored and handled with
care in accordance with the manufacturer's instruc-
tions.
Never use parting grinder discs for roughing work!
Do not apply pressure to the side of parting grinder
discs.
The workpiece must lay flat and be secured against
slipping, e.g. using clamps. Large workpieces must
be sufficiently supported.
If accessories with threaded inserts are used, the
end of the spindle may not touch the base of the
hole on the grinding tool. Make sure that the thread
in the accessory is long enough to accommodate
the full length of the spindle. The thread in the
accessory must match the thread on the spindle.
See page 2 and chapter 14. Technical Specifica-
tions for more information on the spindle length and
thread.
During machining, of metals in
particular, conductive dust can form
deposits inside the machine. This can lead to the
transfer of electrical energy onto the machine
housing. This can mean a temporary danger of
electric shocks. This is why it is necessary when the
machine is running to blow compressed air through
the rear ventilation slots of the machine regularly,
frequently and thoroughly. Here, the machine must
be held firmly.
We recommend using a stationary extractor system
and connecting a residual current circuit-breaker
(FI) upstream. When the angle grinder is shut down
via the FI circuit breaker, it must be checked and
cleaned. For information on cleaning the motor, see
chapter 9. Cleaning.
Dust from material such as paint containing lead,
some wood species, minerals and metal may be
harmful. Contact with or inhalation of the dust may
cause allergic reactions and/or respiratory diseases
to the operator or bystanders.
Certain kinds of dust are classified as carcinogenic
such as oak and beech dust especially in
conjunction with additives for wood conditioning
(chromate, wood preservative). Material containing
asbestos must only be treated by specialists.
- Where the use of a dust extraction device is
possible it shall be used.
- The work place must be well ventilated.
- The use of a dust mask of filter class P2 is recom-
mended.
Follow national requirements for the materials you
want to work with.
Materials that generate dusts or vapours that may
be harmful to health (e.g. asbestos) must not be
processed.
When working in dusty conditions, ensure that
ventilation openings are not blocked. If it becomes
necessary to remove dust, first disconnect the
power tool from the mains supply (use non-metallic
objects) and avoid damaging internal components.
Damaged, eccentric or vibrating tools must not be
used.
Avoid damage to gas or water pipes, electrical
cables and load-bearing walls (static).
Connect a FI circuit-breaker with max.
release current (30 mA) upstream when using the
machine outdoors!
Pull the plug out of the socket before making any
adjustments, converting or servicing the machine.
Metabo S-automatic safety clutch. When the safety
clutch responds, switch off the machine immedi-
ately!
A damaged or cracked auxiliary handle must be
replaced. Never operate a machine with a defective
additional handle.
A damaged or cracked safety guard must be
replaced. Never operate a machine with a defective
safety guard.
This power tool is not suitable for polishing work.
Improper use of the machine will void the warranty!
The motor may overheat and damage the electric
power tool. We recommend using our angle
polisher for polishing work.
See page 2.
1"Quick"clamping nut
2Spindle
3
Autobalancer support flange (non-detachable)*
4 Spindle locking button
5 Sliding
on/off switch *
6 Electronic signal indicator*
7"Protect"
safety switch
5. Overview
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo WBA 11-150 Quick at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo WBA 11-150 Quick in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 4,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info