11
Horizontal checking
Two parallel wall surfaces at least 5m /16‘5“ apart are required for the
horizontal check.
1. Place the PL 5-30 on a smooth surface or on a tripod as close
as possible to wall A and with the front side pointing towards the wall
2. Switch the unit on.
3. Mark the centre of the visible laser dot on wall A (point 1).
4. Turn the complete unit 180° without altering the height of the laser.
5. Mark the centre of the visible laser dot on wall B (point 2).
6. Now move the unit directly in front of wall B.
7. Set the unit‘s height so that the laser dot‘s height matches that of point 2.
8.
Without changing the height of the laser, rotate it 180° to place the beam
near the mark on the  rst wall (step 3 / point 1 ).
Technical data
Laser type: Red diode laser, wavelength 635 nm
Output : < 1 mW, Laser Class 2
to
IEC 60825-1:2007
This product complies with 21CFR parts
1040.10 and 1040.11.
Self-levelling range*:
(horizontal)
Approx. ± 4,5°
Levelling accuracy :
Laser line horizontal*: L1 = ± 0,3 mm/m middle of the laser line
L1 = ± 3/16“ over 50 
90° angle laser beam:* L2 = ± 0,2 mm/m laserl inie
L2 = ± 1/8“ over 50 
Up Beam Accuracy : L3 = ± 0,3 mm / m / ±
3/16“ over 50 
Down Beam Accuracy: L4 = ± 0,4 mm / m / ± 1/4“ over 50 
Batteries : 3 x 1,5 V Mignoncells Alkaline, Size AA, LR6
Operating life : Approx. 20 hours (Alkaline)
Operating temperature range :
-10 °C to +50 °C / -14°F to +122°F
Storage temperature range: -20 °C to +60 °C / -4°F to +140°F
Subject to technical modi cations.
* When operated within speci ed temperature range
F1
F2
F3
F4
S Measured Value
5 m 3,0 mm
10 m 6,0 mm
15 m 9,0 mm
20 m 12,0 mm
S Measured Value
20 ft
1 / 8“
40 ft
9 / 32“
60 ft
7 / 16“
80 ft
9 / 16“
Measure the vertical
distance between
point 1 and point 3.
The di erence must
not be greater than :
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo PL 5-30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo PL 5-30 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 0,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metabo PL 5-30

Metabo PL 5-30 Additional guide - English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info