600614
10
Zoom out
Zoom in
Previous page
1/80
Next page
10
en
Checking plumblining
1. Switch the unit on
2. Place the laser so that its down beam is over a reference mark on the floor.
3. Locate the position of the up beam on the ceiling and make a mark.
4. Rotate the laser 180° and realign the down beam over the reference mark
on the floor.
5. Locate the position of the up beam on the ceiling and make a mark.
6. Measure the di erence D between the two marks on the ceiling,
which will be twice the actual error.
The di erence may not be greater than: 3 mm in 5 m ( 1/8“ in 16‘5“ ).
Checking Level 90° Calibration between horizontal and
right angle
1. Find a room at least 10 m (35 ft) long.
Mark a point (A) on the floor at one end of the room.
2. Set up the laser so that its down beam is over point A.
Make sure the level beam points toward the far end of the room.
3. Mark a point (B) on the floor at the center of the room using a target
to transfer the level beam location to the floor.
4. Mark a point (C) on the far wall or transfer the level beam location to the floor.
5. Move the PL 5-30 to point B and align the level beam to point C again.
6. Mark the location of the square beam (D) on the floor.
Tip:
To ensure accuracy, the distances from A to B, B to C,
and B to D should be equal.
7. Turn the PL 5-30 90° so that the level beam aligns with point D.
8. Mark the location of the square beam (E) on the floor as close
as possible to point A.
9. Measure the distance between points A and E.
Room length or distance
between points A and C
The 90° angle between the level beam
and square beam is out of calibration if
the distance between points A and E is:
10 m > 2,0 mm
20 m > 4,0 mm
32‘10
> 5/64 “
65‘8“
> 5/32 “
E1
E2
G1
G2
G3
G4
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo PL 5-30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo PL 5-30 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 0,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metabo PL 5-30

Metabo PL 5-30 Additional guide - English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info