7. To finish work: Remove the tool from the
workpiece, switch off machine. Let motor come
to a stop, put down machine.
9.1 Change indexable inserts
Regularly check the holder for the indexable inserts
(22). Repair/replace damaged or worn holders for
the indexable inserts.
Regularly check all indexable inserts (20). Change
damaged or worn indexable inserts.
Remove the battery pack from the machine /
pull the plug out of the socket before making
any adjustments, changing tools, carrying out
maintenance or cleaning.
Indexable inserts, holders for indexable
inserts, workpiece and chips can be hot after
work. Wear protective gloves.
Turn/replace blunt indexable inserts or inserts
where the coating is worn in due time. Blunt
indexable inserts increase the risk of the machine
getting jammed and climb out.
Always turn or replace all indexable inserts.
Use only indexable inserts approved by
Metabo. See the Accessories Section.
1. By turning the adjustment ring (13) to the stop,
unscrew the holder for the indexable inserts (22)
as much as possible - this provides good access
to the indexable inserts.
2. Press in the spindle locking button (2) and turn
the holder for the indexable inserts (13) by hand
until the spindle locking button (2) engages.
Keep the spindle locking button (2) pressed.
3. Unscrew the fastening screw (21) and remove
the indexable insert (20).
4. Turn the indexable insert or, if all blades are
blunt, replace the indexable inserts.
5. Fix again the indexable inserts (20) with a
fastening screw (21). Torque: 5 Nm.
6. Turn the adjusting ring (13) in the opposite
direction, so that the holder for the indexable
inserts (22) is again in its normal work range. (So
that the maximum permitted chamfer height is
not exceeded, see chapter Technical
Specifications).
9.2 Replace ball bearing stationary seal ring
(only if required):
Regularly check the ball bearing stationary seal ring
(19) for smooth running. Replace defective ball
bearing stationary seal ring. (order no.: 316093300)
1. Remove screw (18) and remove ball bearing
stationary seal ring.
2. Put new ball bearing stationary seal ring (19) in
place and add screw (18), tighten firmly.
9.3 Adjust scale (only if required):
The graduated ring (12) comes properly set from
the factory.
If indexable inserts are to be used for radii or if the
settings should have been misaligned, the scale
has to be adjusted as follows:
1. Lift the adjustment ring (13) and turn in such a
way that the indexable insert (20) does not
remove any material. (chamfer height = 0 mm)
2. Loosen the two clamping screws (12).
3. Turn the graduated ring (12) until the chamfer
height 0 mm is shown.
4. Tighten the two clamping screws (12).
5. Carry out trial cut.
Chips and particles can deposit at the cutter head.
This can lead to blockage of the cutter head.
Regularly clean the cutter head and its
surroundings and remove chips and particles.
It is possible that particles deposit inside the power
tool during operation. This impairs the cooling of the
power tool. Conductive build-up can impair the
protective insulation of the power tool and cause
electrical hazards.
The power tool should be cleaned regularly, often
and thoroughly through all front and rear air vents
using a vacuum cleaner or by blowing in dry air.
Prior to this operation, separate the power tool from
the power source and wear protective glasses and
dust mask.
11.1 Mains powered machines:
- Overload protection: There is a MAJOR
reduction in load speed. The motor temperature
is too high! Allow the machine to run at idle speed
until it has cooled down.
- Overload protection: There is a MINOR
reduction in load speed.
The machine is
overloaded. Reduce the load before continuing to
work.
- Metabo S-automatic safety shut-down: The
machine has SHUT DOWN by itself. If the slew
rate of the current is too high (for example, if the
machine suddenly seizes or kickback occurs), the
machine switches off. Switch off the machine
using the slide switch (4). Switch it on again and
continue to work as normal. Try to prevent the
machine from seizing. See chapter 4.1.
- Restart protection: The machine does not
start. The restart protection is active. If the mains
plug is inserted with the machine switched on, or if
the power supply is restored following an
interruption, the machine does not start up. Switch
the machine off and on again.
11.2 Cordless machines:
- The electronic signal display (7) lights up and
the load speed decreases. The temperature is
too high! Run the machine in idling until the
electronics signal indicator switches off.
9. Maintenance
10. Cleaning
11. Troubleshooting
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo KFM 9-3 RF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo KFM 9-3 RF in the language / languages: All languages as an attachment in your email.

The manual is 10,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info