600611
9
Zoom out
Zoom in
Previous page
1/64
Next page
en
9
Checking the angular accuracy to 90° :
The check is carried out using the target plate ZP !
1. Select a measuring section with a minimum length of 10 m / 32‘10“.
Mark point A on the
floor
at one end of the section.
2. Align the intersection of the laser lines over point A.
3. Mark point B on the
floor
roughly in the middle of the section and
point C at the end.
4. Move the BLL 2-15 to point B and realign laser line 1 ( L1) on point „C.
5. Mark position „D“ of the right-angle laser line 2 (L2) on the floor.
Note:
For a precise check, the distances from A to B, B to C and B to D should be
approximately the same.
6. Rotate the BLL 2-15 through 90° so that laser line 1 (L1) is aligned with point „D“.
7. Mark the position E of the right-angled laser line 2 (L2) at the shortest
distance to point A on the
floor
.
8. Measure the distance between points „A“ and „E“.
Section between
points A and C
S
Each of the 90° angles are accurately
calibrated if the distance between
points „A“ and „E“ is as follows:
10 m ≤ 3,0 mm
20 m ≤ 6,0 mm
32'10" ≤ 1/8“
6 5 ' 8 " 1 /4
Replacing the batteries
Slide the battery cover (4) in the direction of the arrow and insert new
batteries in accordance with the symbols in the battery compartment.
Suitable batteries can also be used.
Technical data
Laser type: Red diode laser, pulsed line-laser,
wavelength 635 nm
Output: < 1 mW, Laser Class 2 to IEC 60825-1:2007
This product compl. with the appl. requ.
of 21CFR, parts 1040.10 and 1040.11.
Line straightness : ± 0,3 mm/m 3/16“ over 50 
Accuracy 90° angle : ± 0,3 mm/m 3/16“ over 50 
Batteries: 3 x 1,5 V mignoncells Alkaline, Size AA, LR6
Operating life: Approx. 20 hours (Alkaline)
Operating temperature range :
-10 °C to +50 °C / 14°F to +122°F
Storage temperature range: -25 °C to +70 °C / -13°F to +158°F
Subject to technical modi cations.
* When operated within speci
ed temperature range
F
E1
E2
E3
E4
E5
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo BLL 2-15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo BLL 2-15 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 0,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info