Note: If you need to turn the rotary switch to a
lower value because of a machine generating dust
(e.g. small diameter of suction canal in the
machine generating dust, compared to large
suction hose diameter) (5), there is no guarantee
that dust will be conveyed adequately in the
suction hose. The suction hose must be removed
from the machine generating dust after every oper-
ating sequence, so it can be vacuumed clear.
8.1 Dry Vacuuming
Vacuum using a dry filter, dry appliance and dry
accessories only. If the cartridge is damp, dust
may stick and form a crust.
Always use filter cassettes (18) when using paper
filter bags (8), fleece filter bags (7) or PE filter bags
(6) .
8.2 Wet vacuuming
Never operate the machine without inserting
a filter cassette first (18) The machine may be
destroyed and water may also escape.
Vacuum without a paper filter (8) bag. You can use
either fleece filter bags (7) or PE filter bags (6). The
filter cartridges (18) are suitable for wet vacu-
uming.
Before carrying out any wet vacuuming, remove
the dry vacuumed material. This process will
prevent severe soiling and encrustation.
The integrated water sensor switches off the motor
when the container is full. Empty the appliance. If
the appliance is not switched off, the restart
protection device remains effective. The appliance
is not operable again until it has been switched off
and switched back on again.
After switching off, some water may run back out
of the hose.
Before emptying, first of all take the suction hose
out of the liquid.
If you are then going to dry vacuum, insert a dry
filter. If there is frequent switching between dry
and wet vacuuming, we recommend the use of a
second (replacement) filter. Allow the filter,
container and accessories to dry: otherwise dust
may adhere to damp components.
8.3 Special instructions for
ASR 35 M AutoClean:
Use as industrial vacuum cleaner (IS):
Turn switch (2) to the "IR" position.
Adjust the rotary switch (5) to a diameter of 35 mm.
If the volume flow falls below the set value
, the
volume flow control display
lights up to indicate
that the container must be emptied, or that the
paper filter bag (8) /fleece filter bag (7) or the PE
filter bag (8) must be replaced
.
Use as a dust extractor (ENT):
The dust extractor must not be connected to more
than one dust source.
Turn switch (2) to the "AR" position.
Adjust the rotary switch (5) to the hose diameter of
the suction hose fitted. For more detailed informa-
tion, see section 7.5.
Connect the power tool (deactivated) to the plug
socket (4). See section 7.2.
If the volume flow falls below
a
set
value, the filter
cassettes (18) are automatically vibrated (without
any reduction in suction power). If the value
remains too low, the
volume flow control display
lights up and an acoustic signal is also issued:
indicating
that the container must be emptied or
the paper filter bag (8)/fleece filter bag (7) or the PE
filter bag (6)
must be replaced.
8.4 Transport
In the case of the ASR 35 L AutoClean, leave the
hose on the appliance to prevent dust accidentally
escaping.
In the case of ASR 35 M AutoClean, seal the
suction opening (14) with a sealing plug (13) and
join the hose ends to prevent dust from escaping.
Wrap the suction hose about the vacuum cleaner.
Place the accessories in a suitable plastic bag and
seal the bag.
Suspend the mains connection lead on the
cable
holder
(12).
The upper part (9) must be securely sealed to the
container (11) - check that the snap locks (10) are
closed.
9.1 General Cleaning Instructions
Clean the container and accessories with water.
Wipe the upper part (9) with a damp cloth.
Caution! This appliance contains dust that is
harmful to health. Discharge and maintenance
operations (including disposal of the dust collec-
tion containers) must only be carried out by quali-
fied specialists wearing appropriate protective
clothing and equipment.
8Use
9 Cleaning
17027067_0711 ASR 35 L_M AutoClean ENTWURF.book Seite 18 Montag, 25. Juli 2011 4:46 16
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo ASR 35 M ACP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo ASR 35 M ACP in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 10,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info