Recommended separation distances between portable and mobile RF
communications equipment and the MiniMed 640G insulin pump
The insulin pump is intended for use in an electromagnetic environment in which
radiated RF disturbances are controlled. The customer or user of the MiniMed 640G
insulin pump can help prevent electromagnetic interference by maintaining a
minimum distance between portable and mobile RF communications equipment
(transmitters) and the MiniMed 640G insulin pump as recommended below,
according to the maximum output power of the communications equipment.
Rated maximum output
power of transmitter (W)
Separation distance according to the frequency of
transmitter (m)
80 MHz to 800 MHz
d=1.2 P
800 MHz to 6 GHz
d=2.3 P
0.001 0.038 0.073
0.01 0.12 0.23
0.1 0.38 0.73
11.22.3
10 3.8 7.3
100 12 23
For transmitters rated at a maximum output power not listed above, the recommended
separation distance d in meters (m) can be estimated using the equation applicable to
the frequency of the transmitter, where p is the maximum output power rating of the
transmitter in watts (W) according to the transmitter manufacturer.
Note: At 80 MHz and 800 MHz, the separation distance for the higher frequency range
applies.
Note: These guidelines may not apply in all situations. Electromagnetic propagation is
affected by absorption and reflection from structures, objects and people.
Wireless communication
Quality of service
The CGM transmitter and the MiniMed 640G insulin pump are associated as part of
an 802.15.4 network for which the pump functions as the coordinator and the
CGM transmitter as an end node. In an adverse RF environment the MMT-1711
268 Chapter 15
282


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Medtronic MiniMed 640G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Medtronic MiniMed 640G in the language / languages: English as an attachment in your email.

The manual is 23.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Medtronic MiniMed 640G

Medtronic MiniMed 640G User Manual - German - 365 pages

Medtronic MiniMed 640G Additional guide - Dutch - 1 pages

Medtronic MiniMed 640G User Manual - Dutch - 331 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info