790487
16
Zoom out
Zoom in
Previous page
1/80
Next page
8
4 Miscellaneous / 5 Warranty GB
medisana GmbH
Jagenbergstr. 19
41468 NEUSS
GERMANY
Warranty and repair terms
Please contact your supplier or the service centre in case of a claim under
the warranty. Please prepare a copy of your receipt and state what the
defect is.
The following warranty terms apply:
1. The warranty period for medisana products is 3 years from date of
purchase. In case of a warranty claim, the date of purchase has to be
proven by means of the sales receipt or invoice.
2. Defects in material or workmanship will be corrected free of charge
within the warranty period.
3. Repairs under warranty do not extend the warranty period either for the
unit or for the replacement parts.
4. The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g.
non-observance of the user instructions.
b. All damage which is due to repairs or tampering by the customer or
unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to
the consumer.
d. Accessories which are subject to normal wear and tear.
5. Liability for direct or indirect consequential losses caused by the unit
are excluded even if the damage to the unit is accepted as a warranty
claim.
The service centre address is shown on the attached leaet.
4.1 Cleaning and maintenance
Before cleaning the device, make sure that it is turned off and the
mains plug is removed from the socket. Allow the unit to cool down.
Only clean the Shiatsu massage seat cover with a soft cloth slightly
dampened with a mild detergent (e.g. soap suds).
Under no circumstances should you use aggressive detergents,
strong brushes, solvents, petrol, thinners or alcohol. These could
damage the surface.
When cleaning, never immerse the unit in water and make sure that
no water gets into the unit.
Wait until the device is completely dry before using it again.
Do not dry the surface by a hair drier.
4.2 Disposal
4.3 Technical specications
Name and model
power supply
power consumption
Dimensions (mm)
weight
cable lengths
operating conditions
storage conditions
Article No.
EAN number
Loadable up to 100 kg
This product must not be disposed of together with domestic
waste. All users are obliged to hand in all electrical or electro-
nic devices, regardless of whether or not they contain toxic
substances, at a municipal or commercial collection point so
that they can be disposed of in an environmentally acceptable
manner. Consult your local authority or your supplier for infor-
mation about disposal.
In accordance with our policy of continual product improvement,
we reserve the right to make technical and visual changes without notice.
The current version of this instruction manual can be found under www.medisana.com
:
:
:
:
:
:
:
:
:
:
Massage Chair MS 2000/2100 (EC 8601)
220-240 V, 50-60 Hz
85 W
upright: 150x71x120 cm, lying: 178x71x98 cm
approx. 100 kg
Power cord = 190 cm, remote control = 150 cm
0 - 35 °C / 20 - 80 % relative humidity
-5 - 35 °C / 20 - 80 % relative humidity
87708/87709
4015588 87708 7/ 4015588 87709 4
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Medisana MS 2000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Medisana MS 2000 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 4.47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info