643528
9
Zoom out
Zoom in
Previous page
1/42
Next page
Chapter 2
INSTALLATION AND USE MANUAL
page 9
Theoretical notions for installation Technical service – MCZ Group S.p.A. all rights reserved - Reproduction prohibited
2.4. CONNECTION TO THE FLUE PIPE
The connection to the flue pipe is a very important element. The
connection must be made with a great deal of care; in the event of
erroneous or anomalous construction, it is extremely difficult to remedy
without damaging the hood liner. In addition, the connection is made in
a part of the stove where temperatures are very high, and for this
reason it is important to use materials that are capable of resisting heat
and also the acidity of the fumes produced by combustion.
Before beginning work, please note the following:
The connecting pipe must have a maximum slope of 45
degrees. This is to avoid excessive deposit of condensation
produced in the initial phases of lighting the fireplace stove,
and/or the excessive accumulation of creosote. It also keeps
the release of smoke from being slowed down.
The unions must be made of metal and suitable for the
specific operating conditions of the product and marked
EC (EN1856-2). The use of flexible and extending metal
pipes is not permitted.
The components making up the connecting pipe must be
perfectly sealed.
The joint to the flue pipe must not be too long (to avoid
obstructions), nor too short (to avoid smoke leakage).
If metal connecting pipes are used, they must be
insulated with suitable material such as ceramic fibre
matting, to avoid deterioration of the masonry and of
the decorative hood liner.
IMPORTANT!
Any increase in the section of the connecting pipe
must start immediately above the hood of the
fireplace and not along the flue pipe section.
2.5. FLUE PIPE
The flue pipe is a fundamental element in discharging smoke and
therefore must have the following requisites:
be waterproof and thermally insulated.
be made of suitable heat-proof materials that are resistant to
the effects of combustion products and any possible
condensation.
have a vertical arrangement with deviations from the axis of
no more than 45° and without kinks.
must be suitable for the specific operating conditions of the
product and marked EC (EN1856-1, EN1443).
must be suitably sized to accommodate the draught/smoke
disposal requirements necessary for the correct functioning of
the product (EN13384-1).
have an internal section which is preferably circular.
be cleaned if pre-existing and has operated beforehand.
The flue pipe is of primary importance for the correct
functioning and safety of your fireplace stove.
Example of fireplace stove connection
Smoke
connection
Ceramic fibre
insulation
Flue pipe
Hood grille
45° max
Typical diagram of a correctly laid flue pipe
with a chamber including a sealed hatch to
collect and remove solid materials produced
during combustion positioned at the foot of
the external rising section.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ Vivo 70 Wood at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ Vivo 70 Wood in the language / languages: English as an attachment in your email.

The manual is 2,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info