5.8. CONNECTIONS
LINE (1-2 LINEA)
FAN 1 (3-4 VENTIL.)
FAN 2 (5-6VENTIL.)
LIGHT (7-8 AUX)
SWITCH FOR DOOR OPENING (9-10 PORT.)
PROBE (11-12 SONDA)
TERMINAL FOR EARTHING (A)
Connect fans 1 and 2 to the corresponding terminals on the control unit
(3-4 and 5-6).
Connect the probe (11-12); see paragraph 5.6.
For air outlet with light, connect the power cord to the control unit on
the terminals (7-8). For air outlets with a light for natural ventilation,
make the connection to a dedicated switch.
Connect the power cord of the control unit (1-2) to the 230V 50HZ
mains socket.
Once the connections have been made, activate MAN operation and
try turning on the fans to see of they all work. Turn the knob right and
left to test the various speeds.
When connections are complete, install the selected air outlets.