OPERATION
EN / GMDSS Mass Charger Alarm Interface / January 2013 / Copyright © 2013 Mastervolt 7
3.3.1 Main Menu
The Main Menu offers a quick status overview of the
battery system and battery charger. It is immediately
accessible by pressing the Select button shortly. None of
the displayed information can be modified at this menu.
There are two modes to display the measured parameters
at the Main Menu:
Standard menu. If this mode is chosen, all below
mentioned screens will be shown, except the screen
marked with *. (Install menu, F2 = OFF)
Short menu. If this mode is chosen, the screens which
are marked with ** will not be shown. (Install menu, F2
= ON)
The desired mode can be selected at the Install menu,
function F2 (see section 3.3.2).
If the GMDSS Interface is adjusted to the
Standard menu, and function F1: Scroll main
menu is set to ON, scrolling through the Main
Menu is done automatically. If the function F1:
Scroll main menu is set to OFF, you can scroll
through the Main Menu by touching the Select
button shortly.
Status charger
Shows the model of the connected
Mass series battery charger and the
actual charge stage of the Three
Stage Charge algorithm.
Voltage and charge current*
Shows the actual battery voltage
(Volt) and the charge current (Amps).
Charge current**
Shows the actual charge current (%)
as percentage of the nominal charge
current.
Battery voltage **
Shows the actual battery voltage
(Volt).
Battery current**
Shows the actual charge current
(Amps).
3.3.2 Install menu
The Install menu is used to adjust the GMDSS-Interface
in accordance with the electrical installation.
To enter the Install Menu, hold the Select button pressed
for at least 1 second.
To leave the Install Menu wait 20 seconds or scroll to
RETURN and hold the Select button pressed until you
return to the Main Menu.
Touch the Select button shortly to scroll
through the functions as described below.
If a value can be adjusted, the display shows
an arrow. When the arrow is pointing
downwards (È) the displayed value can be
decreased by pressing the Mute button
shortly. If the arrow is pointing upwards (Ç)
the value can be increased.
To change the direction of this arrow, hold the
Select button pressed until the pointing
direction of the arrow changes.
To protect the GMDSS-Interface against
unintended adjustment of set points, the Lock
all settings function is activated every time
you enter the Install menu. When activated
(“ON”), the settings mentioned in this chapter
cannot be changed. See F0 Lock all settings
to unlock.
F0: Lock all settings
To unlock the settings of the GMDSS Interface, hold the
Select button pressed until this function switches to OFF.
Factory setting: ON
Adjustable range: ON/OFF
F1: Scroll main menu
If this function is set to ON, scrolling through the Main
Menu is done automatically. If set to OFF, you can scroll
through the Main Menu manually by touching the Select
button.
Factory setting: ON
Adjustable range: ON/OFF
F2: Main menu short
If this function is set to OFF, all screens mentioned in
section 3.3.1 will be shown, except screen marked with *.
If set to ON, screens marked with ** will not be shown.
Factory setting: OFF
Adjustable range: ON/OFF
M 24/25
Bulk
26.4V
024.0A
CHG CUR.
089%
BAT VOLT
26.4V
BAT CUR.
024.0A
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt GMDSS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt GMDSS in the language / languages: English as an attachment in your email.

The manual is 0.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info