12 February 2011 / AC Power Analyser / EN
Menu Description Default Range
Alarms
Voltage low Voltage is lower than Low voltage setting Read only
Voltage high Voltage is higher than High voltage setting Read only
Current high Current is higher than High current setting.


by the voltage measured,

voltage measured.
Read only
Frequency low Frequency is lower than Low frequency setting Read only
Frequency high Frequency is higher than High frequency setting Read only
History
Minimum [v] Minimum voltage sensed
Maximum [v] Maximum voltage sensed
Energy [kWh] Energy sensed
Clear history Option to clear all history data.
Conguration
Language 
Name 
Relay name 
Relay 
System mode 
Nominal voltage 
Current transfer
primary, sec

Invert current Check box to invert the current measurement
Factory settings Option to reset the AC Power Analyser to
default settings (for installer only).
WARNING: All settings and history data will
be reset!
Frequency low Low frequency alarm level in Hz for 230 (120) V 45 (55) 30–67
Frequency high High frequency alarm level in Hz for 230 (120) V 55 (65) 33–70
Voltage low Low voltage alarm level in V for 230 (120) V 180 (90) 180–275 (90–140)
Voltage high High voltage alarm level in V for 230 (120) V 280 (145) 185–280 (95–145)
MPC reduce [%] MPC reduce level percentage of shore
current, inverter power or generator power
80% 50–100 %
MPC stop [%] MPC stop level percentage of shore current,
inverter power or generator power
90% 60–120%
MASTERBUS FUNCTIONS
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt AC Power Analyser at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt AC Power Analyser in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 6.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info