HUMIDITY GAUGE
•DH 26
Positioned in the front of the appliance. It has a graduated scale
from 1 to 5. When the humidity gauge is set on the minimum
level (1), it means it will work until 80% of relative humidity is
obtained in the room. When it is set on the maximum level (5),
it means the appliance will work until 20% of relative humidity is
obtained in the room. When it is set on “CONT”, the appliance
works continuously no matter what the relative humidity level is.
When it is set on “OFF” the appliance will never start (single pole
switch) (Fig. 4).
•DH 44-62-92
Positioned on the front of the machine. It has a graduated
scale from a minimum of 80% to a maximum of 20% of relative
humidity to be obtained in the room (Fig. 5).
HOUR COUNTER
•DH 26
The hour counter is positioned on the rear of the machine and
indicates the number of hours the appliance has functioned (Fig.
6).
•DH 44-62-92
The hour counter is positioned on the front of the machine and
indicates the number of hours the appliance has functioned (Fig.
6).
FIRST IGNITION
IMPORTANT: In models with dual voltage (...DV), check
the position of the dual voltage switch (220-240V / 110-
120V). If the voltage set does not correspond to the mains
supplied voltage, it is necessary to adjust it. Unscrew the
two securing screws of the cover (Fig. 10), adjust/press
the switch to the correct voltage (Fig. 11) and reassemble
the cover (Fig. 12-13).
Before starting the appliance it must have been in an upright
position (the normal working position) for at least eight hours.
Failure to observe this instruction could cause irreparable
damage to the compressor.
After eight hours the dehumidier can be plugged into a 220-
240 Volt single-phase grounded socket. The “POWER” red
led must switched on to shows that is correctly powered. If
the “WORKING” led is off, turn the humidity gauge knob in a
clockwise direction until it comes on. The “DEFROST” led will
also come on and after about 5 minutes, the dehumidier starts.
If the green “FULL” led is on, the dehumidiers doesn’t start. The
tank must be emptied.
IF THE DEHUMIDIFIER DOES
NOT START OR DOES NOT
DEHUMIDIFY
First of all check the red “POWER” led is on. this shows that
it is correctly powered. Otherwise check if the plug is correctly
connected to the energy supply and if power reach the appliance.
If after these controls the light remains off, take the appliance to
the retailer where it was purchased.
Check the green “FULL” led is off and check the tank is empty.
Check the red “WORKING” led is on, this shows the humidity
gauge required to be in function. When the appliance starts after
a pause because the set humidity level has been reached or
because the tank has been emptied, the “DEFROST” led will
come on, besides the two “POWER” and “WORKING” leds.
They will remain on for about 3 minutes when only the fan will
be working and the compressor will be off.
This cycle is repeated about every 45 minutes to defrost the coil
(evaporator). If the “DEFROST” led remains on for more than
ten minutes take the dehumidier to the retailer where it was
purchased.
If the appliance seems to be working correctly with the
“WORKING” and “POWER” leds on, but no water or very few
is produced, check that the relative humidity in the room is
not lower than 40-45%, otherwise take the dehumidier to the
retailer where it was purchased.
CONNECTION TO A
DISCHARGE PIPE
•DH 26
This dehumidier can be connected directly to a xed discharge
pipe, in which case the tank is removed to enable connecting the
pipe to the coupling.
For the connection, insert the supplied coupling in the right
side of the tank compartment (Fig. 7). Use the supplied rubber
stopper to block the microswitch lever in the left side of the tank
compartment (Fig. 8).
•DH 44-62-92
This dehumidier can be connected directly to a xed discharge
pipe, in which case the tank is removed to enable connecting the
pipe to the threaded male coupling (Fig. 9) (for the model DH 92
remove the plastic connection pre-installed).
For the connection use a pipe with a ¾” female coupling.
PERIODIC MAINTENANCE
The only maintenance that is required is cleaning the lter, the
frequency depending on how dusty the room is and how many
hours the appliance actually works each day.
In normal use it is sufcient to clean the lter once a month, but if
the room is very dusty it should be cleaned more frequently.
The lter is cleaned by washing it under a jet of water in the sink,
owing in the opposite direction to the air ow: the perforated
front panel must face downwards so that the water pushes the
lter against the panel.
After a few years, the hot heat exchanger (condenser) could
need cleaning using compressed air and only a qualied
technician must do this task. This cleaning improves the
appliance efciency and guarantees its long life.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for master DH 44DV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of master DH 44DV in the language / languages: All languages as an attachment in your email.

The manual is 7,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info