588477
10
Zoom out
Zoom in
Previous page
1/72
Next page
1
en
THE UNIT IS SEALED AND CONTAINS
FLUORINATED GREENHOUSE GASES
COVERED BY KYOTO PROTOCOL.
THE “GWP” IS LISTED IN THE “TECHNICAL
SPECIFICATIONS TABLE”.
SAFETY WARNINGS
The dehumidier must always be connected to an
efciently grounded socket. As with all electrical
appliances, failure to observe this safety measure is a
potential source of danger that the constructor does not
respond for in any way.
The appliance must only be dismantled by a qualied
technician using the appropriate tools.
The appliance must always be in an upright position
when it is plugged into an electric socket and must not
be handled with sharp movements. Any water leaking
from the tank or tray could wet the electric parts with the
obvious risk of danger, therefore the dehumidier must
always be unplugged before it is moved and the tank
emptied before it is lifted.
Should any water be spilt due to sharp movements, the
dehumidier must remain turned off and unplugged in an
upright position for at least eight hours before it can be
turned on again.
This dehumidier takes the air in from the rear and expels
it through the front grid, and therefore the rear panel
which holds the air lter must be at a distance of at least
15 centimetres from the wall.
The appliance must not be turned on in conned spaces
where the expelled air from the front grid Is unable to
circulate freely, however the side panels can be placed
next to a wall without affecting the appliance efciency.
This dehumidier has been constructed to the strictest
safety standards. No sharp items (such as screwdrivers,
knitting needles or similar objects) must be introduced
into the front grid or the opening in the rear panel when
the lter is removed as that is extremely dangerous for
human safety and can damage the appliance.
Do not wash the appliance with water; just use a damp
cloth after unplugging it from the socket.
Do not cover the front grid with clothes or other items
as this could damage the appliance and be a source of
danger.
Clean the lter periodically; on average once a month but
if the dehumidier is used in very dusty surroundings
the lter should be cleaned more frequently. Refer to the
specic lter cleaning chapter. When the lter is dirty the
expelled air is hotter than normal and can damage the
appliance and reduces its efciency.
DEHUMIDIFIER
DESCRIPTION
All portable dehumidiers use cooling cycles with compressor.
The appliances are described below.
FUNCTIONS
This dehumidier is an appliance working with a cooling cycle
based on the physical principle whereby the air is exposed
to a cold surface and wets it, giving off humidity as drops of
condensation, or ice if the room temperature is very low.
In practice, a cooling machine keeps a coil cold that the air is
passed through and therefore the air cools down and has the
humidity removed. The air then passes through a hot heat
exchanger and is heated up to return to the room dehumidied
and slightly warmer than at the beginning.
Refer to the diagram (Fig. 1-2):
The air is taken in from the rear of the appliance and passes
through the lter (1), the cold aluminium coil (evaporator) (2),
the hot exchanger (condenser) (3), the fan (4) and nally the
dehumidied air is expelled into the room through the front grid.
The condensed water is collected in the tank (5). A microswitch
(6) stops the appliance when the water in the tank reaches a
set level. The moisture gauge (7) enables the dehumidier to
work when the room humidity is higher than the required level.
An electronic board (8) controls the defrosting and prevents any
dangerous starting of the compressor (9) too soon and delays
its ignition.
These appliances have hot gas defrosting devices installed,
with a solenoid valve for the hot gas bypass, a special electronic
board (with double relay) and a defrosting thermostat.
This defrosting system is exclusive to our appliances: in
practice, a system with a thermostat and electronic control that
uses the hot gas bypass only for the time that is strictly needed,
which lengthens the life of the appliance and reduces the time
of the hot gas phase.
CONTROL PANEL
The control panel is in the front of the appliance and contains
four lighted signals (Fig. 3):
DEFROST (red led): Comes on when the compressor is on
pause or the rst ignition is delayed or during the defrosting
phase.
WORKING (red led): Comes on when the humidity gauge
requests the appliance functions.
POWER (red led): Comes on when the appliance is powered.
FULL (green led): Comes when the condenser tank is full;
when this light is on the appliance stops/does not work.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for master DH 44DV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of master DH 44DV in the language / languages: All languages as an attachment in your email.

The manual is 7,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info