743681
15
Zoom out
Zoom in
Previous page
1/72
Next page
English / Page 15
Electrical connection
Power is supplied to the induction loop detector via the connecting terminal X1 of the
base.
Supply voltage 230 AC, 50 Hz.
On the output side the detector features two potential-free make contacts with the
following functions:
Relay K1: Terminal 10 and 11. Channel 1, 1st loop.
Relay K2: Terminal 7 and 8. Channel 2, 2nd loop.
Impulse without direction logic
If the detector detects a vehicle in the loop field, the relay generates an output impulse
of approx. 1.5 sec. duration.
Presence without direction logic
If the detector detects a vehicle in the loop field, the contact is activated, as long as the
vehicle is on the loop.
Impulse with direction logic
If the detector detects a vehicle in the loop field (channel 1) and then in the loop field
(channel 2), too, the relay K1 generates an output impulse of approx. 1.5 sec. durati-
on.
If the detector detects a vehicle in the loop field (channel 2) and then in the loop field
(channel 1), too, the relay K2 generates an output impulse of approx. 1.5 sec. duration.
Presence with direction logic
I the detector detects a vehicle in the loop field (channel 1) and then in the loop field
(channel 2), too, the relay K1 switches as long as the vehicle is on the loop.
If the detector detects a vehicle in the loop field (channel 2) and then in the loop field
(channel 1), too, the relay K2 switches as long as the vehicle is on the loop.
LED status display
After switching the unit on, the green LED (PWR) indicates that the detector is ready
for operation. When switched on, the red LEDs (CH1 and CH2) flash rapidly and go
out once automatic self-adjustment has taken place.
2. Description of function
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marantec Control 401 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marantec Control 401 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info