English / Page 28
8. Connection and initial operation of the accessories
8.2 External control elements
Function:
The operation of the door system takes place by the commands OPEN, CLOSE,
STOP resp. IMPULSE. For this purpose the respective control elements of
Command range (push button, key switch and code keypad) can be connected
via system plug. For conventional cabling of the impulse button there is a
connection with screw clamps.
In detail the commands cause the following actions:
OPEN : The door is opened. If the door is in end position OPEN and the
automatic timer function is on, the open door time is started again.
CLOSE : The door is closed. If the door is in end position OPEN and the auto-
matic timer function is on, the open door time is terminated.
STOP : A running door is stopped. It can no longer be moved.
IMPULSE : The door is opened (exception: if the door is in end position OPEN, it
is closed).
If the door is in end position OPEN and the automatic timer function
is on, the open door time is started again.
Conventional connection:
• Install the impulse button (A2) to a
well accessible place to the wall
near the door.
• Connect the impulse button via
terminal X2C, contact 1 and 2, to
the control unit (A1), as shown in
fig. 9
• Test the function of the impulse
button.
Fig. 9: Connection impulse button