690576
20
Zoom out
Zoom in
Previous page
1/84
Next page
20
CLEANING OF AIR CLEANER
DANGER: INFLAMMABLES STRICTLY PROHIBITED
Interval of Cleaning and Inspection: Daily (every 10 operating hours)
Turn the choke lever to the full close side, and keep the carburetor off from
dust or dirt.
– Loosenthexingbolt.
Remove the air cleaner cover by pulling its bottom side.
Remove the elements and tap them to remove dirt.
If the elements are heavily contaminated:
Remove the elements, immerse them in warm water or in water-diluted
neutraldetergent,anddrythemcompletely.Donotsqueezeorrubthem
when washing.
– Beforeattachingtheelements,besuretodrythemcompletely.Insufcient
dryingoftheelementsmayleadtodifcultstartup.
Wipe out oil adhering around the air cleaner cover and the breather part with
waste cloth.
Fit the element (sponge) into the element (felt).
Fit the elements into the plate so that the sponge faces the air cleaner cover.
– Immediatelyattachthecleanercoverandtightenitwithxingbolts.(In
remounting,rstplacetheupperclaw,andthenthelowerclaw.)
Plate
Element (sponge)
Air cleaner
cover
Fixing bolt
Element (felt)
Breather Part
POINTS ON OIL
Never discard replaced engine oil in garbage, earth or sewage ditch. Disposal of oil is regulated by law. In disposal, always follow the
relevantlawsandregulations.Foranypointsremainingunknown,contactAuthorizedServiceAgent.
Oil will deteriorate even when it is kept unused. Perform inspection and replacement at regular intervals (replace with new oil every 6
months).
NOTICE:
Clean the elements several times a day, if excessive dust adheres to it.
Dirtyelementsreduceenginepowerandmakestartingenginedifcult.
Remove oil on the elements. If operation continues with the elements
remaining not cleared of oil, oil in the air cleaner may fall outside,
resulting in contamination of the environment.
Do not put the elements on the ground or dirty place. Otherwise they
pick up dirt or debris and it may damage the engine.
Never use fuel for cleaning the elements. Fuel may damage them.
Choke
lever
0.7 mm - 0.8 mm
(0.028” - 0.032”)
CHECKING THE SPARK PLUG
Only use the supplied universal wrench to remove or to install the spark plug.
The gap between the two electrodes of the spark plug should be 0.7 - 0.8 mm
(0.028”-0.032”).Ifthegapistoowideortoonarrow,adjustit.Ifthespark
plug is clogged or contaminated, clean it thoroughly or replace it.
CAUTION: Never touch the spark plug connector while the engine is running
(danger of high voltage electric shock).
Gear case
Grease hole
SUPPLY OF GREASE TO GEAR CASE
Supply grease (Shell Alvania 2 or equivalent) to the gear case through the
grease hole every 30 hours. (Genuine MAKITA grease may be purchased
from your MAKITA dealer.)
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Makita EM2654LHC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Makita EM2654LHC in the language / languages: English, Portuguese, Spanish as an attachment in your email.

The manual is 17,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info