DESCRIPTION
The hood may be in the filtering or the ducting version.
Filtering version (Fig. 1A o 1B): The hood aspirates the kitchen air saturated with fumes and odours, purifies it through
the grease filters and charcoal filters and returns clean air into the room. For constant efficiency, the charcoal filters must
be replaced periodically. The charcoal filters are not supplied.
Ducting version (Fig. 2): The hood aspirates the kitchen air saturated with fumes and odours, passes it through the grease
filters and expels it to the outside through an outlet pipe. With this version the charcoal filters are not required. Decide
from the outset on the type of installation (filtering or ducting). For greater efficiency, we recommend you install the hood
in the ducting version (if possible).
INSTALLATION
ATTENTION: Two persons are required for proper installation; the unit should be installed by a qualified operator.
1. Features of the outlet pipe (only for the ducting version): Before fixing, the outlet pipe for air evacuation to the
outside must be installed. Use an outlet pipe with: – minimum indispensable length; – minimum possible bends (maximum
angle of bend: 90°); – certified material (according to the State); – an as smooth as possible inside. It is also advisable
to avoid any drastic changes in pipe cross-section (recommended diameter: 150 mm). For air evacuation to the outside,
follow all the other instructions given on the “Warnings” sheet.
2. Prepare the electric power supply (for the electric connection, follow all other indications stated on the “Warning”
sheet). If the model you have purchased is supplied with a decorative flue, prepare the electric power supply within
the decorative flue.
3. Assembly of the metal grid (only for the filtering version of the extractor hood without decorative flue): the
metal grid must be assembled by operating inside the hood, therefore:
- For models with metal panels: Remove the upper panel gripping it on the right (or left) and pulling until the 2 internal
pins are released. Operate in the same way on the opposite side of the panel; slightly move the panel upwards until
the 2 tabs slip out of the slots (Fig. 3). Remove the upper grease filter by pushing the catch downwards and turning
the filter outwards (Fig. 4).
- For models with glass panels: Open the upper panel by gripping it at the bottom (Fig. 5). Remove the upper grease
filter by pushing the catch downwards and turning the filter outwards (Fig. 4).
- Proceed with fitting the metal grille securing it with 2 screws from the inside of the hood (Fig. 6).
4. Assembly of the charcoal filter (only for the filtering version): check that the charcoal filters have already been
installed. Rest them on the sides of the motor and turn them in an anti-clockwise direction (Fig. 7).
5. Assembly of the flange (only for the ducting version): install the flange in the device air outlet and press slightly
(Fig.8).
6. Fixing to the wall: Draw a line on the wall in vertical line with your hob. Mark the first 4 holes to be drilled in the wall,
respecting the distances indicated in Fig. 9. Drill the 4 holes and fit the screw anchors provided. Fix the metal brackets
(A) to the wall using the holes just drilled (Fig. 10); the screws for fixing the bracket are provided.
Hang the hood on the brackets (Fig. 11). Adjust the horizontal position moving the hood to the right or left so that it is
aligned with the wall units. When adjustment has been completed, without removing the hood, mark the other 2 holes to
be drilled (C) in the wall. Remove the hood and drill the holes marked (8 mm diameter). Then use the 2 screw anchors and
the 2 screws provided for final fixing.
Refit the grease filter and close the upper panel.
7. Fixing of the telescopic decorative flue (the decorative flue is only present in certain models):
- Adjust the width of the support bracket (D) of the telescopic flue by means of the screws (E) as shown in Fig.12; then,
by means of the screw anchors and screws (F) provided, fix the bracket to the ceiling in such a way that it is positioned
along the axis with your hood.
- Only for the ducting version: Connect the air outlet pipe to the air vent of the hood. Use a flexible pipe and lock it to
the air vent of the hood with a metal hose clamp - Fig. 13 (pipe and clamp are not provided).
- Only for the filtering version: Mount the flange on the hood in correspondence to the air outlet point (Fig. 14). Take the
air baffle and fit a flexible pipe to it (125 mm diameter) locking it with a metal hose clamp (pipe and clamps are not provided).
Fit the air baffle to the upper flue (Fig. 15) with 4 screws. Connect the flexible pipe to the flange on the air vent (Fig. 16).
- Carry out the electrical connection of the hood using the power supply cable.
- Insert the extension flues setting them on the hood; extend the upper flue to the ceiling and secure with the 2 screws
(H) - Fig. 17.
OPERATION
Depending on the model, the unit is equipped with the following controls:
CONTROLS shown in Fig. 18:
A) Turns the LIGHTS off
B) Turns the LIGHTS on.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for M-System MST-90 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of M-System MST-90 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info