Velocity Curve: The Velocity Curve Select key (Vel Curve) is used to change the touch sensitivity of the keyboard or
pads. This setting lets you decide how the force with which you hit a key affects the volume at which a note plays.
Oxygen 49 keyboards provide 7 different sensitivity options:
1: C1 generates lower velocity values for the same force. This setting is useful for playing more quietly, even if you
tend to strike the keys harder.
2: C2 is the default setting, and is designed to be useful for most players with an "average" touch (people who play
with an average amount of force).
3: C3 generates higher velocity values for the same force. This setting is useful for playing more loudly, even if you
tend to strike the keys with less force.
4: C4 generates an equal velocity value for a given amount of force, resulting in a linear (or neutral) keyboard
response.
5: F1 is a setting that effectively disables sensitivity, meaning the keyboard will generate a fixed velocity value of 64
(on a scale of 0-127) regardless of how hard or soft the keys are struck.
6: F2 is a setting that effectively disables sensitivity, meaning the keyboard will generate a fixed velocity value of 100
(on a scale of 0-127) regardless of how hard or soft the keys are struck.
7: F3 is a setting that effectively disables sensitivity, meaning the keyboard will generate a fixed velocity value of 127
(on a scale of 0-127) regardless of how hard or soft the keys are struck.
1. Press the Edit button.
2. Press the Velocity Curve (Vel Curve) key (press Velocity Curve key twice to edit pad velocity settings). The LED
display will show the current velocity curve (for example, ".C.0.2").
3. Type the Velocity Curve number (1 through 7) using the number keys.
4. Press the Enter key.
- or –
1. Press the Edit button.
2. Press the Velocity Curve (Vel Curve) key (press Velocity Curve key twice to edit pad velocity settings). The LED
display will show the current velocity curve (for example, ".C.0.2").
3. Use the "<" or ">" buttons to scroll through the Velocity Curves (C1 through F3).
4. Press the Enter key.
Drawbar Mode: This parameter switches all 9 faders to Drawbar Mode. In this mode, the operation of the faders is
reversed, so that the maximum value (127) is at the bottom and the minimum value (0) is at the top. This feature is
intended for use with Organ presets that utilize drawbars.
1. Press the Edit button.
2. Press the Drawbar key. The LED screen will momentarily display "On". Drawbar Mode becomes active
immediately and Edit mode exits automatically. Repeat steps 1 and 2 to disable Drawbar Mode. The LED
screen will momentarily display "OFF".
Memory Dump: The SysEx Memory Dump function (Mem Dump) will send the contents of all 10 Preset memory
locations for storage in a DAW application. Please refer to the documentation provided with your DAW software for
information on how to record SysEx MIDI data.
1. Prepare a MIDI track within your DAW software to record from your Oxygen 49 keyboard.
2. Press the Edit button on your Oxygen 49 keyboard.
3. Start the MIDI recording in your DAW software.
4. Press the Memory Dump key on your Oxygen 49 keyboard. The SysEx memory dump will begin immediately
and the LED screen will display "SYS" to indicate that data is being sent. The SysEx file will appear as a new
MIDI recording in your DAW software.
Restoring a Memory Dump:
IMPORTANT: Restoring a saved Memory Dump will permanently overwrite all current presets on your Oxygen 49
keyboard. Restored settings will not become active until a new preset is loaded on your Oxygen 49 keyboard, or the
device has been powered off and on.
Play back a MIDI track that contains a previously recorded Oxygen 49 SysEx Memory Dump. The SysEx data is sent
back to the Oxygen 49 keyboard. The Oxygen 49 LED screen will display "SYS" while receiving the SysEx data.
Device ID: The Device ID function (DEV ID) allows the assignment of a unique SysEx Device ID to differentiate
between multiple MIDI devices of the same model, when sending or receiving SysEx data.
The default setting of 127 lets the keyboard respond to all incoming SysEx messages compatible with the same type
of Oxygen 49 keyboard controllers. However, if the Device ID is changed to any other value, the keyboard will only
respond to SysEx messages that contain the same Device ID number. This is useful in situations where multiple
Oxygen 49 controller keyboards are connected to the same DAW software and SysEx information needs to be sent
to a specific keyboard controller with a unique Device ID number.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for M-Audio Oxygen 49 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of M-Audio Oxygen 49 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 2,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info