Digital Input Status – Just below the Volume Faders on the Digital In panel are two
status indicators. The top indicator delineates professional or consumer channel
status with PRO or CON labels. Professional status is generally associated with
an AES/EBU signal, and consumer status is generally associated with an S/P DIF
signal. The bottom indicator shows Lock/Unlock status or an error code for the
digital input:
Code Color DIGITAL IN Status/Error
Lock Green Locked and receiving audio data flagged as valid.
Lock Yellow Locked and receiving audio data flagged as invalid.
Unlock Red Not locked – caused by an unstable signal or loss of connection.
Conf Red Indicates a degraded signal typically caused by long or lossy
cables.
Biphase Red Indicates a signal that violates the biphase encoding rules.
Parity Red Indicates a signal that does not have even parity.
CRC Red Indicates a signal whose CRC channel status does not match the
calculated CRC.
These indicators are updated four times per second.
MonitorEnables or disables input monitoring for each output device. The Monitor
Source control selects which input is monitored. The monitor circuitry on the
LynxONE digitally mixes the selected monitor source with the output signal with
a one sample period delay. Because of this extremely low delay, the use of the
LynxONE’s monitor function is recommended instead of the monitoring features
of third party applications when performing overdubs.
Mute – Provides a mute function for each associated input or output.
Input / Output Activity Indicators – The names at the bottom of the analog and
digital I/O panels reflect the name of its associated wave device. When a device is
inactive its name is shown as blue text. When a device is active (currently open
for play or record) its name appears in black with a green background.
Sample Clock – This section of the LynxONE mixer provides control of the sample
clock source and reference. Since the sample clock is the master timing source, all
LynxONE audio devices on a single card must have identical sample rates. Sample
clock settings cannot be changed if any LynxONE audio device is playing or
recording.
Source Allows selection of the sample clock source from one of the following:
Internal – Clock derived from the on-board crystal oscillator.
External – Clock signal from the CLOCK IN connector on the MIDI/Clock
cable.
Header – Clock signal from the board-mounted CLOCK IN header.
Digital – Clock signal from the DIGITAL IN connector on the Audio cable.
The Digital Format control must be correctly selected when selecting
this clock source.
Reference – Provides selection of the clock source reference type from one of the
following:
Mixer Reference
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lynx ONE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lynx ONE in the language / languages: English as an attachment in your email.

The manual is 0,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info