No LED SynchroLock is disabled by remote control or the source is outside of SynchroLock range
and the Aurora has reverted back to the wide-range analog PLL. If SynchroLock failed
to lock, you can tap through the SYNC SOURCE options to return to the original source
to re-engage the SynchroLock clocking system.
r TO ANALOG OUT
This button selects the signal source that will be routed to the analog outputs. This is a global
selection, affecting all analog channels. Channels are mapped to directly corresponding channels (i.e.
In 1 to Out 1, In 2 to Out 2, etc.). Individual channels may be routed to specific output destinations
when the external control is used. Choices are:
ANALOG IN Signals from Analog In 1-16
Aurora 8 Signals from Analog In 1-8
AES IN Signals from Port A and Port B Digital In
Aurora 8 Signals from Port A Digital In
LSLOT IN Signals from LSLOT expansion device inputs (for instance ADAT lightpipe)
All 3 LEDs ON In this mode, front panel routing has been bypassed, and routing will be managed by
external control.
t TO DIGITAL OUT
This button selects the signal source that will be routed to the digital outputs. As with the TO
ANALOG OUT selection, this setting impacts all digital channels, whereas per channel routing is
possible with external control. It is possible to route digital inputs to digital outputs, allowing the
Aurora to function as a standalone digital router. Channels are mapped to directly corresponding
channels (i.e. In 1 to Out 1, In 2 to Out 2, etc.). Signal Choices are:
ANALOG IN Signals from Analog In 1-16
Aurora 8 Signals from Analog In 1-8
AES IN Signals from Port A and Port B Digital In
Aurora 8 Signals from Port A Digital In
LSLOT IN Signals from LSLOT expansion device inputs (for instance ADAT lightpipe)
All 3 LEDs ON In this mode, front panel routing has been bypassed, and routing will be managed by
external control.
y IR/MIDI
This LED illuminates to indicate activity from the MIDI input or IR transceiver. This could indicate
that the external control software is being used or that the firmware is being programmed via IR or
MIDI.
u PEAK METERS
These meters display the instantaneous peak level of audio being sent to the Aurora analog or digital
inputs. The intensity of the lower row of orange LEDs indicates signal strength. The upper row of red
LEDs indicate overload.
i IR Transceiver
The infrared transceiver mounted on the front panel of the Aurora provided the ability to control
parameters and view level meters and settings via handheld, laptop or desktop PC with Infrared
capabilities. However, this functionality is no longer supported with current firmware updaters and the
Aurora Remote Control software.
o METER
This button determines whether the peak meters display input activity for the digital or analog inputs.
This button also determines the behavior of the TRIM/AES MODE controls. When the ANALOG
LED is ON the meters indicate the levels for the analog inputs and outputs and the TRIM/AES MODE
button controls the TRIM. When the DIGITAL LED is ON the meters indicate the levels for the digital
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lynx Aurora 16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lynx Aurora 16 in the language / languages: English as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info