Water speed averaging (sonar transducer)
Averages water speed by measuring your speed at a selected
interval of time. Water speed intervals range from one to thirty
seconds, e.g. if you select  ve seconds, your displayed water speed
will be based on averaging over 5 seconds of sampling.
Calibration range: 1-30 seconds. Default is 1 second.
Water temperature calibration (sonar transducer)
Temperature calibration is used to adjust the water temperature
value from the sonar transducer to match the data from another
temperature sensor. It may be required to correct for localized
in uences to the measured temperature.
Calibration range: -9.9° - +9.9°. Default is 0°.
Note: Water temperature calibration only appears if the transducer is
temperature capable. Check transducer type selection if this option
should be available.
Transducer type
Transducer type is used for selecting the transducer model
connected to the sonar module. The transducer selected will
determine what frequencies the user can select during sonar
operation. In some transducers with built-in temperature sensors,
the temperature reading may be inaccurate or not available at all if
the wrong transducer is selected. Transducer temperature sensors
are one of two impedances - 5k or 10k. Where both options are
given for the same model transducer, refer to paperwork supplied
with transducer to determine impedence.
StructureScan and SpotlightScan
These features are both enabled automically when a transducer is
plugged in before the unit has been powered on. The SpotlightScan
transducer has a 83/200 kHz element incorporated, which requires
connection to the ‘Sonar port. This transducer has XID (transducer
ID), so manual selection of the transducer is not required.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lowrance HDS Gen3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lowrance HDS Gen3 in the language / languages: English as an attachment in your email.

The manual is 7,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Lowrance HDS Gen3

Lowrance HDS Gen3 User Manual - English - 184 pages

Lowrance HDS Gen3 Quick start guide - German - 8 pages

Lowrance HDS Gen3 User Manual - German - 176 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info