1. Does the opener have electric power? Plug a lamp into the outlet. If it doesn't light,
check the fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.)
2. Have you disabled all door locks? Review installation instruction warnings on page 7.
3. Is there a build-up of ice or snow under the door? The door may be frozen to the
ground. Remove any restriction.
4. The garage door spring may be broken. Have it replaced.
5. Repeated operation may have tripped the overload protector in the motor. Wait 15
minutes. Try again.
Having a Problem?
Situation Probable Cause & Solution
The opener doesn't
operate from either
the Door Control or
the remote control:
Opener operates from
the remote, but not
from Door Control:
1. Is the door control lit? If not, remove the bell wire from the opener terminals. Short the
red and white terminals by touching both terminals at the same time with a piece of
wire. If the opener runs, check for a faulty wire connection at the door control, a short
under the staples, or a broken wire.
2. Are the wiring connections correct? Review Step 6, page 14.
The door operates
from the Door
Control, but not from
the remote control:
1. Is the door push bar flashing? If your model has the Lock feature, turn it
off.
2. Your opener needs to re-learn a remote control code. Refer to instructions on the
opener panel.
3. Program the receiver to match the remote control code.
4. Repeat the receiver programming procedure with all remote controls.
The remote control
has short range:
The garage door
opens and closes
by itself:
1. Be sure that all remote control push buttons are off.
2. Remove the bell wire from the door control terminals and operate from the remote
only. If this solves the problem, the door control is faulty (replace), or there is an
intermittent short on the wire between the door control and the opener.
3. Clear memory and reprogram all remote controls.
The door doesn't
open completely:
1. If the door has been working properly but now doesn't open all the way, increase the
up force.
See page 25.
2. Is something obstructing the door? Remove the obstruction or repair the door.
3. If door opens at least 5 feet, the travel limits may need to be increased. One turn
equals 2 inches of travel. See page 24.
Repeat the safety reverse test after the adjustment is complete.
The door stops but
doesn't close
completely:
Review the travel limits adjustment procedures on page 24.
Repeat the safety reverse test after any adjustment of door arm length, close
force or down limit.
1. Change the location of the remote control in your car.
2. Check to be sure the antenna on the side or back panel of opener extends
fully downward.
3. Some installations may have shorter range due to a metal door, foil backed insulation,
or metal garage siding.
Opener noise is
disturbing in living
quarters of home:
If operational noise is a problem because of proximity of the opener to the living
quarters, the Vibration Isolator Kit 41A3263 can be installed. This kit was designed to
minimize vibration to the house and is easy to install.
30
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Liftmaster 1280-298LMC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Liftmaster 1280-298LMC in the language / languages: English as an attachment in your email.

The manual is 1,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info