It is possible to transfer the data to the PC in real time when conducting extensive measurements where
there is not sufÖ cient space in the internal memory for the recorded data. Data storage takes place directly
at the PC. The measured data can also be displayed and observed directly on the PC monitor.
11
Real time recording (SEND DATA)
Connect the device to the PC as described under Point 10 and
start the program. Press and hold the "SEND DATA" button
for 3 seconds to start data transfer. "SENDING" appears on
the display. All recorded data are now shown in real time on
the PC. Press the "SEND DATA" button again for 3 seconds to
stop data transfer.
3 sec
The device is equipped with analogue signal outputs. The dB A or dB
C signal is output via the CD output for connection to a chart recor-
der for instance. The unÖ ltered signal that is recorded directly from
the microphone is made available at the AC output for a possible
connection to an oscilloscope.
12
DC/AC output
The calibration can be checked by means of a sound pressure level
calibrator in accordance with IEC/EN 60942:2003ff. The calibrator
deÖ nes a target volume of 94 dB. The device should be checked in
the 80...130 dB setting and show 94 dB plus the tolerance range on
the display. If the displayed value deviates from the target volume,
you can adjust the sound level meter to the required 94 dB by means
of the calibration screw.
13
Calibration and adjustment
It is recommended to operate the device with a controlled power
pack (9 V, > = 500 mA DC, DC power plug 3.5 x 1.3 mm). High
quality control and Ö ltering of the power pack is required in order
to rule out possible interference on the measurement signal (ripple
<= 100 mV).
14
Power pack operation
For certain measuring tasks it may be of advantage to secure the device on a tripod. To do so, screw the
device on to a tripod with a 1/4" connection. Undo the device by turning in anticlockwise direction.
15
Mounting on tripod
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laserliner SoundTest-Master at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laserliner SoundTest-Master in the language / languages: English, German, Dutch, French, Finnish as an attachment in your email.

The manual is 0,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info