Index mode is used to rapidly locate moisture with comparative
measurements, without a direct output of material moisture in %.
The output value (0 through 1000) is an indexed value that increases
as material moisture becomes greater. Measurements made in index
mode are independent of material type and particularly useful with
materials for which no characteristics are stored. When comparative
measurements reveal strongly deviating values, the course of
moisture in the material can be localized quickly.
The wet/dry LED indicator is programmed in line with the relevant material characteristics so the LEDs also
provide information about whether the material should be classiÖ ed as dry, moist or wet.
However the values in index mode, which is independent of the material type, are output on a neutral scale
whose value increases as the moisture level rises. The LED indicator can be speciÖ cally programmed for index
mode by deÖ ning the end values for “dry” and “wet”. The difference between the value set for “dry” and
that set for “wet” is converted and displayed by the 12 LEDs.
Setting the wet/dry threshold values in index mode
15
Index mode
Index mode can be used in both resistance measurement as
well as in capacitive measurement. See Step 6 and 10 for setting
index mode.
20
GB
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laserliner MultiWet-Master at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laserliner MultiWet-Master in the language / languages: All languages as an attachment in your email.

The manual is 12,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info