GB
A photoelectric sensor is used to measure the incident light intensity.
This is the power of the radiated light per unit of area. Photometry
deÖ nes light in terms of how it is perceived by the human eye. The
sensitivity of the eye also depends on the wavelength or light colour.
The measuring unit uses special colour Ö lters on the sensor that
adapt to the sensitivity curve (CIE curve).
After switching on the device, press the „Lux“ button.
Please observe the following application notices when
determining illuminance:
Align the sensor on the measuring surface so it is perpendicular to
the light source
During measurement, the incidence of light must not be affected
by shadows from the operator or other objects not involved in the
measurement
– Remove the wind de× ector from the microphone
You can check the measuring device‘s zero position by covering the
sensor completely.
Discharge, × uorescent or energy-saving lamps should be switched
on well in advance of the measurement process (approximately 15
minutes) so that the brightness has time to stabilise
By pressing the „Mode“ button, you can get the device to display the
highest (MAX), lowest (MIN), average (AVG) or difference value (DIF)
in addition to the current measured value. As its name suggests, the
„HOLD“ button enables you to hold the current measured value.
Illuminance (lux)
7
SET
HOLD
MODEMODE
dB
TEMP/%RH
UNIT
ANEMO
LUX
The device measures radiation in the main direction, perpendicular to the sensor plane. Incident
light rays at an angle are taken into account by the sensor using an adjustment curve.
!
Reference values for illuminance in indoor spaces
Practical example Luminous intensity in lux
TrafÖ c areas, ancillary rooms 20
Corridors in buildings used by people 50
Sanitary facilities, machine rooms, staircases 100
Regularly occupied work stations within production facilities, canteens 200
Conference rooms, gyms 300
OfÖ ces, medical facilities (emergency unit) 500
Design and drawing rooms 750
Monitoring locations, assembly rooms, test stations 1000
Assembly rooms for small components 1500
The amount of light available in outdoor spaces is approximately 100
times greater than in indoor spaces. In the event of a high incidence
of light, the measured value on the display is reduced by a factor of
10 or a factor of 100.
SET
HOLD
MODEMODE
dB
TEMP/%RH
UNIT
ANEMO
LUX
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laserliner MultiTest-Master at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laserliner MultiTest-Master in the language / languages: All languages as an attachment in your email.

The manual is 7,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info