CALCULATION OF THE THERMAL POWER
There is not an absolute rule for calculating the correct necessary power. This power is given according to the space to be heated, but it
depends also largely on the insulation. On an average, the caloric value necessary for a properly insulated room is 30 kcal/h per m
3
(for an
external temperature of 0°C).
Given that 1 kW corresponds to 860 kcal/h, it is possible to adopt a value of 35 W/m
3
.
Let’s suppose one wishes to heat a room of 150 m
3
(10 x 6 x 2.5 m) in an insulated apartment. In this case, it is necessary to have 150 m
3
x 35
W/m
3
= 5250 W or 5,25 kW. As main heating, a 8 kW device is therefore sucient.
 

 
kcal/h

    
    
    
    
    
    

  
   
    
MAINTENANCE ON THE WATER SYSTEM
Excessive incrustation deposits on the inner walls of the hearth considerably reduce the eciency of heat exchange; therefore,
remove these deposits using a steel brush whenever necessary. Never use corrosive substances that can damage the thermo-
replace and the boiler.
With the system switched o, once a year carry out the following checks:
Check the operation and eciency of the blowdown and safety valves. If they are defective, contact your authorised installer. IT IS
STRICTLY FORBIDDEN TO REMOVE OR TAMPER WITH THE SAFETY DEVICES.
Check the thermal insulation of the lling pipe and the safety pipe.
Make sure that the system is lled and under pressure, checking the water level in the expansion tank; also check that it is working
properly and check the eciency of the safety pipe.
MAINTENANCE OF THE EXTENSIBLE GUIDES
To work silently, as well as in a reliable and robust way, the doors are fastened to the extensible ball guides. By using the device continuously,
the lubricant of the guides tends to run out progressively in time making their sliding more dicult and noisy. For this reason, together with
each device a high temperature grease is supplied in order to make the lubrication of the guides possible for the user, in case it becomes
necessary (excessive noise or reduction of smoothness). After having completely lifted the door of the stack, using a syringe, apply internally
on the track on a visible point, as high as possible, two grease balls (corresponding to 0.5 ml of the graduated scale of the syringe).
Pay attention not to exceed the suggested quantity. Repeat the same operation on the other track and lift and lower the door many
times so that the grease distributes on all balls.
CAUTION: use exclusively the grease supplied by La NORDICA.
When the cleaning is completed: - put the top cap of the replace into its place (B). You have to support the cap to the wall above the replace
by passing it through the corresponding slots (C) and then, with a rotary movement of the hand, send the screws at the machined seats
into the wall (D) and leave the cap as support on the upper wall; - put into its place the top lock steel plate of the replace as indicated in
Picture 10 pos. E.
ATTENTION: The absence of the cap (B) and the top lock steel plate of the replace (E) causes a strong depression, leading
to excessively fast combustion and excessive wood consumption, with consequent overheating of the appliance, forge
eect, and decreases the heat discharge of the boiler.
34
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica Termocamino Base DSA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica Termocamino Base DSA in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 9,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info