-16-
5 Technical data
5.1 CO2 CONTROL sensor unit
Technical data
Alarm thresholds:
1.5% - visual/audible pre-alarm
3% - visual/audible main alarm
Method of measurement:
Selective IR absorption
Measurement range/volume flow:
0 - 5 vol. % / diffusion
Cross-sensitivity:
negligible
Connection:
RS485 bus connection
3 m control line, 4-wire
Max. control line length
(extension via distributor)
max. 100 m to the warning unit
Power supply:
via warning unit (7 - 20 V DC)
Temperature range:
Storage temperature range
Operating temperature range
-30 °C to + 70 °C
-30 °C to + 40 °C
* < 0 °C requires acclimatisation prior to operation
Visual display/audio
LED green Power light
LED yellow Malfunction / 70 dB alarm sound
LED red Alarm / 70 dB alarm sound
Readiness for operation:
Immediately following initialisation (*after
acclimatisation)
Dimensions (H x W x D):
80 x 108 x 80 mm
Weight:
325 g
Protection rating:
IP54
Fastening
via DIN rail, perpendicular to the wall
Certified according to:
TRSK 313, test no. 432 - 986701
* For use in one freezer cell
5.2 CO2
CONTROL PA warning unit
Technical data
Alarm thresholds:
1.5% - visual/audible pre-alarm
3% - visual/audible main alarm
Malfunction
Yellow LED flashes plus audible warning sound
Connection:
RS485 bus connection
3 m control line, 4-wire
Mains cable, 2.5 m, incl. angled plug
PA warning unit version
4 floating outputs, external power supply up to
60 VDC/125 VAC at max.0.5 A, 3 m control line
5-wire
Rated voltage:
Rated current / rated output:
230 V / 50 Hz
10 mA / 6 W
Temperature range:
Storage temperature range
Operating temperature range
-20 °C to +70 °C
0 °C to +40 °C
Readiness for operation:
Immediately following initialisation
Visual display:
LED green Power light
LED yellow Malfunction
LED red Alarm
Audible warning
>90 dB
Weight:
200 g
Protection rating:
Design protection class:
IP54
Protection class II
Dimensions (H x W x D):
125 x 80 x 52 mm
Device plug-in possibilities:
max. 2 sensor units
max. 2 actuators (signal unit / switching unit)
Certified according to:
TRSK 313/DIN 6653-2
Test no. 432 986701, EC conformity 2013
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kundo xT CO2 Control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kundo xT CO2 Control in the language / languages: English as an attachment in your email.

The manual is 1,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kundo xT CO2 Control

Kundo xT CO2 Control Usermanual and installation guide - German - 54 pages

Kundo xT CO2 Control Usermanual and installation guide - German - 53 pages

Kundo xT CO2 Control Usermanual and installation guide - Dutch - 52 pages

Kundo xT CO2 Control Usermanual and installation guide - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info