27
The pressure gauge shows full
pressure although the gun has been
closed. The pressure switch valve
switches constantly.
Possible cause no.1: Leakage
Having closed th gun, the HP cleaner must shut
down and the pressure gauge must show „0“
bar. If the pressure gauge still shows full pres-
sure and the motor constantly switches on and
off, the possible reason for this can be a leakage
of the pump, the HP hose or the lance.
Proceeding:
Check the connections from the HP cleaner to
the the HP hose, from the hose to the gun and
also the connection between lance and gun for
tightness. Switch off the cleaner. Shortly press
the trigger of the gun to decrease the pressure.
Unscrew HP hose, gun and lance and check the
O-rings. If the O-rings are damaged they have to
be replaced.
In case of a leakage there is no guarantee for
possible consequential damages.
Possible cause no. 2:
The non-return valve is soiled or
defective
Proceeding:
Unscrew pump outlet.
Take out non-return valve body and check for
soiling or damage of the O-ring.
Replace non-return valve if necessary.
There is no guarantee if the pump is
damaged by defective O-rings due to air
induction or lack of water (cavitation).
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle therm 601 E-ST 18 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle therm 601 E-ST 18 in the language / languages: English as an attachment in your email.

The manual is 3,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle therm 601 E-ST 18

Kranzle therm 601 E-ST 18 User Manual - German - 60 pages

Kranzle therm 601 E-ST 18 User Manual - French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info