Troubleshooting
Diagnosis using light diodes on control panel
The location of the diodes on the control panel is shown on page 27.
Malfunction Possible cause Action
High pressure pump
operates but burner fails to
ignite
Ignition cable defective
Ignition transformer defective
Burner motor (M2) defective
Coupling between burner motor
and fuel pump defective
Fuel pump defective
Fuel magnetic valve (Y1) dirty or
defective
Press switch (S3) or (S5)
defective
Contactor (K3) defective
Check and replace if necessary
Check and replace if necessary
Check and replace if necessary
Check and replace if necessary
Check and replace if necessary
Clean, check, replace if
necessary
Check and replace if necessary
Check and replace if necessary
IMPORTANT!
The system must be
connected to the power
mains when the LEDs
are checked.
You must therefore be
as careful as possible.
Disconnect the system
from the power mains
as soon as possible
afterwards.
Remove the plug from
the socket!
Diode Illuminates when
Diode D7 must light up directly after the system is
switched on, otherwise check fuses F1 and F2 on the
circuit board.
D7 Motor start-up allowed
- heating element press switch (S5) in
rest position or re-run delay active
D11 Excess temperature not exceeded
- Klixon (S1) not actuated
D12 Magnetic valve release illuminates 3.5 seconds after D17
D16 Motor start-up allowed
- heating element press switch (S5) in rest position
D17 Burner start-up allowed
- Thermostat (B1), flow controller (S2)
and pump press switch have actuated
D18 Low oil level
- float switch oil control (S4) closed
D20 In case of sensor breakage refer to Flame Monitor
Sensor.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle Therm 1165 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle Therm 1165 in the language / languages: English as an attachment in your email.

The manual is 2,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle Therm 1165

Kranzle Therm 1165 User Manual - German - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info