508528
19
Zoom out
Zoom in
Previous page
1/52
Next page
Troubleshooting
Malfunctions without display
Malfunction Possible cause Action
Machine fails to start No electrical voltage at
machine
Master switch defective
Motor protection switch
actuated
Press switch (S3 or S5)
defective
Motor protection (K3) switch
defective
Check power supply and cables
Check and replace if necessary
Eliminate cause of overload
Check and replace if necessary
Check and replace if necessary
High pressure pump runs but
burner fails to ignite
Set water temperature
reached
Pre-ventilation time not yet
elapsed
Ignition switched off
Fuel tank empty, "OIL"
display at thermostat
Thermostat defective
Ignition switch defective
Float switch in fuel tank
defective
Fuel filter dirty
Fuel nozzle defective
Flow controller (S2) has
switched off
Contact of flow controller
defective or incorrectly set
Ignition contacts incorrectly
set or burned out
Increase target water
temperature, open gun with
machine on until water
temperature drops
Hold gun open for approx 5
seconds
Ignition switch "ON"
Refill fuel
Check and replace if necessary
Check and replace if necessary
Check and replace if necessary
Check and clean if necessary
Check and replace if necessary
Check water inflow; clean filter in
water tank
Readjust, check, replace
Readjust, check, replace
19
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle Therm 1165 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle Therm 1165 in the language / languages: English as an attachment in your email.

The manual is 2,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle Therm 1165

Kranzle Therm 1165 User Manual - German - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info