General rules
General rules
Oil leakage
If oil leaks contact your nearest after-sales service (dealer) at once.
(environmental damage, damage to the transmission).
In case of increased humidity or fluctuations in temperature
development of condensed water is possible. If the oil turns grey
or white, you must change it.
Oil change
New oil: 0, l
Kränzle high-performance transmission oil (Item no. 40.093 2)
or Motor oil 10 W - 60 SAE.
Range of application
Use high-pressure cleaner for cleaning purposes only using high-pressure jet with
or without cleaning detergent.
Environmental, refuse disposal and water protection regulations
must be observed!
Inspections
The high-pressure cleaner was finally inspected by the company Kränzle (refer to
Kränzle final report).
The high-pressure cleaner must be inspected according to the “Guidelines for
Liquid Spray Devices” at least once every 12 months by a qualified person, to
ensure that continued safe operation is guaranteed. The results of the inspection
are to be recorded in writing (see Inspection reports).
High-pressure cleaners used for commercial purposes have to be
checked by a qualified person at least every 12 months!
The owner is to ensure that all safety-relevant components are in a
serviceable condition before the high-pressure cleaner is used.
Accident prevention
The high-pressure cleaner is designed for accidents to be impossible if used
correctly. The user is to be notified of the risk of injury from hot machine parts
and the high-pressure jet. The “Guidelines for Liquid Spray Devices” must be
complied with.
During the combustion process air is needed and exhaust gas emerges.
If the high-pressure cleaner is operated in a confined space, precau-
tions have to be taken to safely exhaust the fumes. Furthermore a
sucient ventilation has to be provided for.
During the combustion process air is needed and exhaust gas emerges.
If the high-pressure cleaner is operated in a confined space, precau-
tions have to be taken to safely exhaust the fumes. Furthermore a
sucient ventilation has to be provided for.
The first oil change should be carried out
after approximately 50 operating hours,
then every year or after 250 operating
hours. If the oil turns grey or white, you
must change the oil. In case of exchan-
ging oil being required, the oil drain screw
must be opened above a container and the
high-pressure cleaner be emptied. The oil is
to be caught in the reservoir and disposed
of in an approved manner.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle Therm 1017 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle Therm 1017 in the language / languages: English as an attachment in your email.

The manual is 8,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle Therm 1017

Kranzle Therm 1017 Additional guide - English, German - 23 pages

Kranzle Therm 1017 User Manual - German - 29 pages

Kranzle Therm 1017 User Manual - Dutch - 29 pages

Kranzle Therm 1017 User Manual - French - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info