English
Settings and queries
The settings and queries can be carried out using the remote control or the control panel.
Settings
To enter the setting mode, press the setup button on the control panel.
To change the settings, press [#] + [code] + parameters + [#].
To exit the setting mode, press [*] + [#].
Setting Command Remarks
Record voice message [#] + [19] + message + [#] Voice message duration: max. 10 seconds.
Add remote control [#] + [07] + [xxx] + [#]
[xxx] = remote control ID (001-120). After adding, press a button on the remote control.
2beeps = remote control added succesfully. 1beep = remote control already congured.
Max. number of remote controls: 120.
Delete remote control [#] + [08] + [xxx] + [#] [xxx] = value of remote control to be removed.
Delete all remote controls [#] + [08] + [***] + [#] [***] = all connected remote controls.
Add detector [#] + [09] + [xxx] + [#] [xxx] = detector ID (001-120). Max. number of detectors: 120.
Delete detector [#] + [10] + [xxx] + [#] [xxx] = value of detector to be removed.
Delete all detectors [#] + [10] + [***] + [#] [***] = all connected detectors.
Set up phone number(s) [#] + [3] + [y] + phone number + [*#]
[y] = phone number ID (1-9).
ID 1-6 = regular phone numbers. ID 7-9 = emergency phone numbers.
Delete phone number(s) [#] + [3] + [y] + [#] [y] = phone number ID (1-9).
Setup password [#] + [50] + password + [#] The password has a maximum of 4 digits. Default password: 1234.
Setup arming delay time [#] + [51] + seconds + [#] Seconds from 00 to 99. Default = 00.
Setup alarm delay time [#] + [52] + seconds + [#] Seconds from 00 to 99. Default = 60.
Setup siren time [#] + [53] + minutes + [#] Minutes from 00 to 20. Default = 01.
Setup date and time
[#] + [56] + year + month + day +
hour + minutes + seconds + [#]
Example: “20141025183500” = October 25, 2014 18:35:00.
Setup alarm clock
[#] + [57] + [yy] + start time + end
time + day(s) + [#]
[yy] = 05 / 06 (max. 2 alarms).
Example 1: “050900090112345” = siren sounds for 1 minute on weekdays at 09.00.
Example 2: “051030103167” = siren sounds for 1 minute during weekends at 10:30.
Delete alarm clock [#] + [57] + [yy] + [0] + [#] [yy] = 05 / 06.
Setup remote control by
telephone
[#] + [62] + [y] + [#] [y] = 0 (o) or 1 (on). Default = 1 (on).
Setup number of rings for
remote control by telephone
[#] + [18] + [yy] + [#] [yy] = 00 (o) - 99. Default = 8.
Setup audible feedback [#] + [11] + [y] + [#] [y] = 0 (o) or 1 (on). Default = 1 (on).
Volume audible feedback [#] + [79] + [y] + [#] [y] = 0 (o) - 7 (loud).
Display brightness control [#] + [83] + [y] + [#] [y] = 0 (dark) - 7 (bright).
Set up power-saving mode [#] + [84] + [y] + [#] [y] = 0 (o) or 1 (on). Default = 1 (on).
Volume built-in siren [#] + [87] + [y] + [#] [y] = 0 (o) - 7 (loud).
Setup display light ashing [#] + [88] + [y] + [#] [y] = 0 (o) or 1 (on). Default = 0 (o).
Setup telephone line connection
detection
[#] + [13] + [y] + [#] [y] = 0 (o) or 1 (on). Default = 0 (o).
Disable use of remote control for
arming/disarming
[#] + [15] + [y] + [#] [y] = 0 (o) or 1 (on). Default = 0 (o).
Setup interference prompts [#] + [16] + [y] + [#]
If other devices try to connect to the alarm system, the siren will sound for 5 seconds.
[y] = 0 (o) or 1 (on). Default = 0 (o).
Setup control panel lock [#] + [17] + [y] + [#] [y] = 0 (o) or 1 (on). Default = 0 (o ).
Add wireless strobe siren
(option)
Press the “SET button on the strobe
siren to enter start code learning.
Press the disarm button on the
control panel. The strobe siren beeps
once to indicate that the learning
process is completed successfully.
Contact your local reseller for availability.
Volume external siren
(option)
[#] + [14] + [yy] + [#] [yy] = 00 (o) - 99 (loud).
Restore factory settings for
control panel
[#] + [9898] + [#]
System reset [#] + [989801] + [#]+ [#]+ [#] Caution: The entire alarm system is restored to the factory settings.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Konig Electronic SAS-ALARM240 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Konig Electronic SAS-ALARM240 in the language / languages: All languages as an attachment in your email.

The manual is 1,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info