Timer Setting
Press the Timer button to enter timed shutdown. Upon shutdown, press this button to enter timed
start. In the meanwhile, the timer indicator illuminates. Press the Timer button to enter timed
start/timed shutdown. Adjust the up or down button to set the timing time. The time will cycle in
the order of 1 to 24 to 1. The adjustment time of the timing function is relative time.
After timed start is set, once the timed start time is reached, the unit will start. In the meanwhile,
the timer indicator will extinguish and the ambient temperature is displayed.
After timed shutdown is set, once the timed shutdown time is reached, the unit will shut down. In
the meanwhile, the timer indicator will extinguish and the ambient temperature is displayed.
ON/OFF operations caused by the button or remote control will clear all timing settings.
Once the timing is determined, if the timer button is pressed once, it is possible to query the re-
maining timed start/shutdown time. If the timer button is pressed twice continuously within 5s, it
is possible to cancel timing.
Protection Functions
Anti-freeze protection function
If the compressors operates continuously for more than 10 minutes and the pipe temperature is less
than 2°C continuously for 20 seconds, the compressor and water spraying motor turn o. LED dis-
plays E4 and the unit initiates the anti-frost protection function and the buttons are inactive (except
the OFF button). Once the pipe temperature exceeds 8°C, the protection is relieved, the original sta-
tus is restored and the unit meets the requirements for 3-minute delay protection of the compressor.
Full water protection function
When the water in the water tray exceeds the alarm level, the unit will alarm automatically and the
full water indicator illuminates. In this case, you need to drain the condensate in the unit; otherwise,
the unit will shut down automatically after the buzzer gives o 5 beeps. The unit will be restored to
the previous operating status automatically once the water is fully drained.
Delay protection function of the compressor
This unit oers restart protection for the compressor. Except that the compressor may start immedi-
ately when the unit is energized for the rst time, there is 3-minute delay start protection after the
compressor is shut down.
Water Tank and Continuous Drainage
Wassertank manuell entleeren
Once the unit shuts down upon full water, turn o the power of the unit and then unplug the power
plug. Move the unit carefully to avoid spillage of water in the water tray at the bottom of the unit
Put the vessel that holds water below the
water outlet at the back of the unit.
Screw o the drain cap, unplug the water
plug and water will ow into the vessel that
holds water automatically. If the vessel that
holds water can not hold all water in the unit,
before the vessel that holds water is full of
water, block the water outlet with the water
plug as soon as possible to prevent the water
from owing onto the ground or carpet.
IMPORTANT: Protect the drain cap and water plug properly. Tilt the unit slightly backward when
draining. Turn on the unit only after the water plug and drain cap are installed properly; otherwise,
the condensate of the unit will ow onto the ground or carpet.
16
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Klarstein 10028188 Pure Blizzard 3 2G 3-in-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Klarstein 10028188 Pure Blizzard 3 2G 3-in-1 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 5,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info