Installation and operation manual“
5
KFD stove must be installed on fireproof surface. If stove is going to be placed on wooden
floor or similar combustible surface, it must be preserved with high temperature (fire)
resistant material. Floor must be preserved under and around the stove.
Local regulations in exact country have the primacy of information presented in this
manual.
All local standards and regulations regarding to distance of the wall and exhaust pipe.
2.2 Chimney
After stove installation the stoves air outlet must be connected with exhaust gas pipe. This
connection should be made with attested pipe which can be used into solid fuel fireplaces. Its
diameter should match the air outlet diameter. If there is any need of reducing this diameter
use proper reduction connectors. Connection between reduction and the stove must be
sealed. The last phase of connecting the stove with the chimney is assembling the
connection pipe with the chimney.
The chimney must have at least as much air as you need for a normal combustion of the
appliance and the ventilation of the place. Respect the UNI 10683 norm relative to the
ventilation openings.
Basic requirements for chimney pipes, which are used for stove connection are:
- Chimney pipe must have round cross-section area,
- It should be heat isolated and waterproof, made of materials which are resistant to
high temperatures, exhaust emission products,
- It cannot have any reductions or deviations bigger than 30 º,
- For rectangular cross-section the bigger side ratio should not be higher than ½,
- The minimum height of chimney pipe should be 4 meters counting from the place
where fireplace is connected into it,
- It should have washout which allows to gather and remove all remaining of exhaust
process,
- Too big cross-section of the chimney pipe might cause problems with the way how the
device works,
- Too small cross-section area of the chimney pipe might greatly reduce the devices
draft and make it fume.
The under pressure into chimney should be around 10-12 Pa. It should be measured during
the work of the stove. When the under pressure is more than 17 Pa, installation of the
moderator should be considered to lower and stabilize it.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for KFD STO MAX 7 3F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of KFD STO MAX 7 3F in the language / languages: English as an attachment in your email.

The manual is 1.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info