Voice 2
Pressing the key that is assigned with “VOICE2” announces the S
meter and power meter values. For example, “S5” or “20 dB” will
be announced in this case.
Press [PF B] or the PF key that is assigned with
“VOICE2”.
Announces the S meter and power meter values.
Pressing the PF key that is assigned with “VOICE1”,
“VOICE2” or “VOICE3” during the announcement stops
the announcement.
For more details on how to change the assignment of PF
keys, please refer to “PF Keys (Programmable Function
Keys)” (16-2).
Even while an analog meter is displayed, the “VOICE2”
announcement changes according to the level when a
digital meter is displayed (dot: 0 to 70).
Content that is announced in the VOICE2 mode is as follows.
S meter
Power Meter
Level
Content of
Announcement
Level
Content of
Announcement
0 S 0 0 P 0
1 to 4 S 1 1 to 5 P 5
5 to 8 S 2 6 to 10 P 10
9 to 12 S 3 11 to 14 P 17.5
13 to 16 S 4 15 to 19 P 25
17 to 20 S 5 20 to 27 P 37.5
21 to 24 S 6 28 to 35 P 50
25 to 28 S 7 36 to 47 P 75
29 to 32 S 8 48 to 59 P 100
33 to 36 S 9 60 to 65 P 125
37 to 41 10 dB 66 to 70 P 150
42 to 47 20 dB - -
48 to 52 30 dB - -
53 to 58 40 dB - -
59 to 64 50 dB - -
65 to 70 60 dB - -
Voice 3
Pressing the key that is assigned with “VOICE3” announces the
meter values.
Press [PF C] or the PF key that is assigned with
“VOICE3”.
Announces the meter value at the time when the key is pressed.
VOICE3 makes announcement only during
transmission.
Pressing the PF key that is assigned with “VOICE1”,
“VOICE2” or “VOICE3” during the announcement stops
the announcement.
For more details on how to change the assignment of PF
keys, please refer to “PF Keys (Programmable Function
Keys)” (16-2).
Even while an analog meter is displayed, the “VOICE3”
announcement changes according to the level when a
digital meter is displayed (dot: 0 to 70).
When the meter selected is PWR meter, the
announcement is the same as that of the PWR meter in
VOICE2.
Pressing [VOICE3] while the voice message recording
standby screen or the voice message recording in
progress screen is displayed announces the value
(recording level) of the “Recording Level Meter”.
Pressing [VOICE3] during configuration of the
microphone gain in Advanced Menu [10] announces the
value of the level meter.
Content that is announced in the VOICE3 mode is as follows.
SWR Meter COMP Meter ALC Meter
Level
Content of
Announcement
Level
Content of
Announcement
Level
Content of
Announcement
0 to 1 R 1.0 0 C 0 dB 0 A 0
2 R 1.1 1 to 9 C 5 dB 1 to 2 A 1
3 to 4 R 1.2 10 to 19 C 10 dB 3 to 4 A 2
5 R 1.3 20 to 34 C 15 dB 5 to 6 A 3
6 to 7 R 1.4 35 to 50 C 20 dB 7 to 8 A 4
8 to 9 R 1.5 51 to 57 C 25 dB
9 to 10 A 5
11 to 12 A 6
10 to 11 R 1.6
58
onwards
C OVER 13 to 14 A 7
12 to 13 R 1.7
15 to 16 A 8
14 to 15 R 1.8
17 to 18 A 9
16 to 17 R 1.9
19 to 20 A 10
18 to 21 R 2.0
21 to 22 A 11
22 to 27 R 2.5
23 to 24 A 12
28 to 36 R 3.0
25 to 26 A 13
37 to 42 R 4.0
27 to 28 A 14
43 to 47 R 5.0
29 to 30 A 15
48
onwards
R OVER
31 to 32 A 16
33 to 34 A 17
35
onwards
A OVER
ID Meter TEMP Meter VD Meter
Level
Content of
Announcement
Level
Content of
Announcement
Level
Content of
Announcement
0 to 9 I 2.5 0 to 25 T LOW
Up to 46
V LOW
10 to 17 I 5 26 to 60 T MIDDLE 47 to 48 V 10
18 to 26 I 7.5
61
onwards
T HIGH 49 to 51 V 11
27 to 35 I 10
52 to 55 V 12
36 to 44 I 12.5
56 to 58 V 13
45 to 52 I 15
59 to 61 V 14
53 to 60 I 17.5
62 to 64 V 15
61
onwards
I 20
65
onwards
V HIGH
Recording Level Meter/
Audio Lever Meter during FM Microphone Gain Configuration
Level Content of Announcement
0 L 0
1 to 2 L 1
3 to 4 L 2
5 to 6 L 3
7 to 8 L 4
9 to 10 L 5
11 to 12 L 6
13 to 14 L 7
15 to 16 L 8
17 to 18 L 9
19 to 20 L 10
21 to 22 L 11
23 to 24 L 12
25 to 26 L 13
27 to 28 L 14
29 to 30 L 15
31 to 32 L 16
33 to 34 L 17
35 onwards L OVER
13 VOICE GUIDANCE
13-12
146


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-890S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-890S in the language / languages: English as an attachment in your email.

The manual is 21,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-890S

Kenwood TS-890S User Manual - German - 196 pages

Kenwood TS-890S User Manual - Dutch - 196 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info