15 TROUBLESHOOTING
OPERATION NOTICES
The transceiver has been designed and engineered to
avoid possible hardware glitches. However, you may
notice the following symptoms when you operate the
transceiver. These symptoms are not malfunctions.
DC POWER SUPPLY
As stated in the SPECIFICATIONS {page 80}, this
transceiver requires a supplied DC voltage source of
13.8 V ±15%. If you fi nd that the transceiver cannot
be switched ON, or that it shuts OFF automatically, the
DC voltage may be outside the specifi ed range.
In such a case, remove the DC cable from the
transceiver immediately and confi rm that the supplied
voltage is within the specifi ed range.
INTERNAL COOLING FAN
The transceiver detects the temperature of the
nal department regardless of the transmission
and reception state of the main body, in order to
protect the internal circuits from high temperatures.
The cooling fan speed and transmission output is
controlled through the following.
When the thermistor detects a rise in temperature
in the fi nal department, the cooling fan turns on at
low speed. As the temperature rises, the speed of
the cooling fan increases.
When an abnormally high temperature is detected,
the temperature protection circuit activates,
reducing the transmission output to the lowest
possible power.
When the temperature protection circuit activates,
return the transceiver to receive mode and leave the
transceiver power ON. Allow time for the cooling fan
to return the internal temperature to normal.
If you turn the transceiver power OFF, the cooling
fan will not run and it will take much longer for the
internal temperature to decrease.
INTERNAL BEATS
On some spots of the receiver frequencies, the
S-meter moves or you cannot receive any signals.
This is inevitable when you use superheterodyne
receivers. You may notice the signals on the following
spots of the frequency:
• 15.600.00 MHz
• 31.200.00 MHz
• 46.800.00 MHz
AGC
When you turn the AGC function OFF {page 30}, the
receiving audio signals can be distorted. In this case,
decrease the RF gain, turn the pre-amplifi er OFF, or
turn the attenuator ON. In general, the RF gain must
be greatly reduced when the AGC is turned OFF.
60 m BAND OPERATION
Effective from July 3, 2003, FCC Report and Order
(R&O) in ET Docket 02-98 granted US amateurs
secondary access to fi ve discrete channels in the
vicinity of 5 MHz. General, Advanced, and Amateur
Extra licensees may use the following fi ve channels
on a secondary basis with a maximum effective
radiated power of 50 W PEP relative to a half wave
dipole. Only upper sideband suppressed carrier voice
transmissions may be used. The frequencies are
5330.5, 5346.5, 5366.5, 5371.5 and 5403.5 kHz. The
occupied bandwidth is limited to 2.8 kHz centered on
5332, 5348, 5368, 5373, and 5405 kHz respectively.
The TS-590SG transceiver stops at the 60 m band
as you scroll up or down the amateur radio frequency
bands. For more information, contact ARRL or search
their Web site using the key word “60 meter”:
http://www.arrl.org
92


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-590SG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-590SG in the language / languages: English as an attachment in your email.

The manual is 4,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-590SG

Kenwood TS-590SG User Manual - German - 96 pages

Kenwood TS-590SG User Manual - Dutch - 96 pages

Kenwood TS-590SG User Manual - French - 96 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info