12 SCAN
MEMORY SCAN
Memory Scan monitors all memory channels in which
you have stored frequencies (All-channel Scan) or only
a desired group of memory channels (Group Scan).
Scan automatically stops at a channel where a signal
is present, regardless of the operating mode. The
transceiver will either remain on that channel for a
short time (Time-Operated mode) or until the signal
drops out (Carrier-Operated mode). Use Menu No.
11 to select the mode. The default is “to” (Time-
Operated).
SCAN RESUME METHOD
The transceiver stops scanning at the frequency (or
memory channel) where a signal is detected. It then
continues scanning according to which resume mode
you have selected. You can choose one of the
following modes. The default is Time-operated mode.
•Time-Operated mode (“to”)
The transceiver remains on a busy frequency (or
memory channel) for approximately 6 seconds,
then continues to scan, even if the signal is still
present.
Carrier-Operated mode (“co”)
The transceiver remains on the busy frequency (or
memory channel) until the signal drops out. There
is a 2 second delay between signal dropout and
scan resumption.
1 Press [MENU/ F.LOCK] to enter Menu mode.
2 Turn the MULTI control to select Menu No. 11.
3 Press [ ]/ [ ] to select “to” (Time-Operated) or
“co” (Carrier-Operated).
4 Press [MENU/ F.LOCK] to complete the setting
and exit Menu mode.
You can lock out the memory channels that you
prefer not to monitor while scanning. To do this, refer
to “Memory Channel Lockout” {page 54}.
ALL-CHANNEL SCAN
Use the following procedure to scan all the memory
channels that contain frequency data in sequence,
ignoring the Memory Group number.
1 Select Time-operated or Carrier-operated mode
via Menu No. 11.
2 Press [A/B / M/V] (1 s) to enter Memory Recall
mode.
3 Turn the SQL control to adjust the squelch
threshold to mute the speaker.
4 Press [SCAN/ SG.SEL] (1 s) to enter Scan Group
Select mode.
•Turn the MULTI control to select the Memory
channel group.
MGROUP–0 represents Memory channel 0 ~
9, MGROUP–1 represents Memory channel 10
~ 19 and so on up to MGROUP–9 which
represents Memory channel 90 ~ 99 {page 53}.
5 As you select the Memory Groups using the
MULTI control, press [ ] to select “oFF” for all
Memory Groups.
6 Press [SCAN/ SG.SEL] to return to Memory
Recall mode.
7 Press [SCAN/ SG.SEL] to start All-channel Scan.
Scan starts from the current memory channel
and ascends up through the channel numbers.
(The scan direction cannot be changed.)
•To jump to a desired channel while scanning,
turn the MULTI control, or press Mic [UP]/
[DWN].
8 To stop Scan, press [SCAN/ SG.SEL] or
[MTR/ CLR].
Note:
If you have turned the
SQL
control clockwise, far beyond the
squelch threshold, Scan may fail to stop at a channel where a
signal is present. If this happens, turn the
SQL
control slightly
counterclockwise.
Starting Memory Scan switches OFF the RIT and XIT functions.
66


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-480SAT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-480SAT in the language / languages: English as an attachment in your email.

The manual is 6,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-480SAT

Kenwood TS-480SAT User Manual - German - 104 pages

Kenwood TS-480SAT User Manual - Dutch - 104 pages

Kenwood TS-480SAT User Manual - French - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info