511233
28
Zoom out
Zoom in
Previous page
1/64
Next page
23
7 SCAN
To perform the Program Scan, the following conditions must
be met. Otherwise, the Band scan starts {page 22}.
The upper and lower limit frequencies are in the same
frequency band.
Ln < Un (where “n” is the Program Scan channel number).
MHz SCAN
MHz Scan allows you to scan an entire 1 MHz
frequency range within the current VFO frequency.
1 Press [VFO].
2 Turn the Tuning control or press [ ]/ [ ] to select
a frequency in which to perform the MHz Scan. If
you want to scan the entire 145 MHz frequency,
select any frequency between 145.000 and
149.995 MHz (for example, select 145.650 MHz).
Scan will operate between 145.000 MHz and
145.999 MHz.
3 Press [MHz] (1 s) to start the MHz Scan.
4 To stop the MHz Scan, press [MHz] or [PTT].
Note:
If the Fine Tuning function is ON, you cannot perform the MHz
Scan.
If you press [MONI], MHz Scan temporarily pauses. Release
[MONI] to resume scanning.
PROGRAM SCAN
You can limit the scanning frequency range. There
are 10 memory channel pairs (L0/U0 ~ L9/U9)
available for specifying the start and end frequencies.
It monitors the range between the start and end
frequencies that you have stored in memory channels
L0/U0 to L9/U9. Before performing the Program
Scan, store the Program Scan frequency range to
one of the memory channel pairs L0/U0 ~ L9/U9.
Storing Program Scan Frequency Range
1 Press [VFO].
2 Press [BAND] to select your desired band.
3 Turn the Tuning control or press [ ]/ [ ] to
select your desired start frequency.
4 Press [F], then turn the Tuning control or press
[ ]/ [ ] to select a memory channel from L0 ~
L9.
5 Press [MR] ([ ] or [MNU]) to store the start
frequency in the memory channel.
6 Turn the Tuning control or press [ ]/ [ ] to
select your desired end frequency.
7 Press [F], then Turn the Tuning control or
press [ ]/ [ ] to select the corresponding
channel from U0 ~ U9 (you must select the
same numeric value as in step 4).
For example, if you selected L0 in step 4,
you must select U0 in this step.
8 Press [MR] ([ ] or [MNU]) to store the end
frequency in the memory channel.
Performing the Program Scan
1 Press [VFO].
2 Turn the Tuning control or press [ ]/ [ ] to
select a frequency within the frequency range
of memory channel L0/U0 ~ L9/U9.
3 Press [VFO] (1 s) to start the Program Scan.
4 To stop the Program Scan, press [VFO] or
[PTT].
Note:
If you press [MONI], Program Scan temporarily pauses.
Release [MONI] to resume scanning.
If the Fine Tuning function is ON, the scanning does not stop
at the busy channels.
The transceiver stops scanning in all modes when it detects
a signal.
If more than 2 Program Scan channel pairs are stored and
overlaps the frequency range among the pairs, the smaller
Program Scan memory channel number has the priority.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TH-F7E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TH-F7E in the language / languages: English as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TH-F7E

Kenwood TH-F7E User Manual - Dutch - 64 pages

Kenwood TH-F7E User Manual - French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info