5.4 Warnings/error messages
Certain internal and external problems will result in error messages and in some cases
further actions. For example:
If you attempt to start a weld without the ow of shielding gas, pressing the
start weld switch will result in an error message. The weld start sequence will
be terminated.
If gas ow is interrupted during the weld sequence, welding will be terminated
and the indicated error message will say: Weld Aborted: Check Gas Supply.
Message during welding
1. Welding Aborted Check gas supply
2. Welding Aborted Check water cooler, hoses and connections.
3. Arc Strike failure Reload when ready.
4. Arc failure Reload when ready.
5. OSC Out of Limits Comments shown in level screen during welding.
6. OSC Maybe Jammed Comments shown in level screen during welding.
7. OSC Out of Limits and Jammed Comments shown in level screen during welding.
8. Master Slave Comm Error Check master slave board
9. Slave Reset Error Check slave board
Communication Error between Pendant and Controller
Communications failure Press Main to try again or call Kemppi for help
Message during creating, editing, copying, deleting and setup
1. Autoprogram Failure Improper head selected; select 300-series weld head.
2. Autoprogram Failure Wall thickness and OD must be greater than zero.
3. Autoprogram Failure Wall thickness must be less than pipe radius.
4. Autoprogram Failure OD and/or wall thickness is out of range for the
selected weld head.
5. Program Failure This weld head is not supported by current software.
6. New Weld Creation Guide ring factor must be greater than zero with the
selected weld head.
7. New Weld Creation Guide ring factor must be less than 1638 with the
selected weld head.
8. New Weld Creation OD should be less than 163 inch with the selected
weld head.
9. New Weld Creation OD should be less than 4140 mm with the selected
weld head.
10. Autotack Failure Improper weld head selected; must be R or C head.
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A7 TIG Orbital System 300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A7 TIG Orbital System 300 in the language / languages: English as an attachment in your email.

The manual is 4,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info