A7 TIG Orbital System 300© Kemppi Oy 2016 1615
OPERATING MANUAL
3.9 Completing the programming
Press Main to exit to Main Menu. Press Run to immediately
weld with new program.
Editing a weld program
Move cursor to Edit. Press Select.
Use the cursor to select an item. Modify with the
control knob.
Certain items may not be modied. The cursor will
bypass these items.
Use Next to move through levels, editing them
as you go. The edited weld will overwrite the
original program if the same weld number is
selected.
3.10 Updating software
The controller units application software can be
updated. Updates are not done regularly, and they are
recommended only when some new feature or bug x
is needed. Updating can be done via USB media. Consult
Kemppi workshop service for detailed instructions when
updating.
3.11 Welding
1. Create a new program or choose one from the
library.
2. Activate the Run/Ready screen.
Screen shows the status of the weld head
position, AGC inhibit, and wire inhibit.
Screen allows purge of backing gas and coolant.
Water and gas are purged with the same button. Make
your selection pressing the arrow up. Text on the bottom
right corner changes from purge to water and back to
purge.
3. Start welding by pressing the Arc On button.
3.12 Travel speed correction
Compared with the electrode tip, the weld head rotates
further away from the pipe surface. This makes the actual
rotation speed of the electrode tip slower than that of the
weld head.
Correction factor = the weld head rotation
diameter divided by the electrode tip rotation
diameter
The factor may be small on large pipes, but it can
become signicant with small diameters, when modifying a
pre-established program to new pipe size.
In heavy wall pipe welding, the groove progressively lls
and electrode rotation diameter retracts closer to the
guide ring diameter. In these cases, you may need to
change the diameter in correction factor calculation. The
correction factor should be 17 mm + groove depth for the
given pass where 17 mm is the radial height of the guide
ring.
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A7 TIG Orbital System 300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A7 TIG Orbital System 300 in the language / languages: English as an attachment in your email.

The manual is 4,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info