686409
12
Zoom out
Zoom in
Previous page
1/61
Next page
12
A7 TIG Orbital System 300© Kemppi Oy 2016 1615
OPERATING MANUAL
Guide ring
The guide ring consists of:
Two hinged segments closed around the pipe
and latch
Two xed stainless steel "pads" mounted in
one-half of the guide ring that provide a "Vee-
block" to square the guide ring relative to the
pipe axis
Pads dimensioned so that the guide ring is
centred on the pipe as long as the pipe is within
nominal outer diameter (OD) size range.
If the pipe is either under or oversized, do one of the
following:
Shorten the pads.
Use longer pads to maintain concentricity.
Substitute pads with alternate pads to allow a
guide ring designed for a larger pipe size to be
mounted concentrically on a smaller pipe size.
Clamp the guide ring rigidly on the pipe using setscrew(s)
on the other half of the ring.
Guide rings for 8" and larger pipes are supplied as two-
piece units that are bolted together by two recessed
captive socket-head screws.
To specify guide ring kit P/N (see related charts):
The part number for the 300-series weld head
guide rings also indicates the workpiece
diameter in inches. For example, a 2" pipe is
2.375" OD .
If radial clearance is important for an
application, use appropriate size guide ring for
the minimum radial clearance.
Or use a guide ring for the next smaller size
down by replacing the insert pads.
To specify guide ring insert kit P/N (see related chart):
To use a guide ring on a smaller size pipe or
tube, substitute dierent steel pad "inserts" for
the those supplied standard. The last 3 digits of
the part number indicate the height of insert
pad in inches.
Example: To weld a pipe 0.5" (12.7 mm) smaller
in OD. than nominal pipe size of guide ring,
0.5"/2 = 0.25" radial clearance between new
pipe OD. and guide ring. Insert should be 0.25"
in height. Therefore P/N is 102222-250 (250
standing for .250).
A longer setscrew may be required depending on the
length of the insert. This is provided if required as part of
the insert kit.
To position the guide ring:
Place the guide ring approximately 60.00 mm +/-
1 mm from the weld joint in order to eliminate
the need for mechanical adjustments of the
head.
Place the ring as square as possible to the weld
joint to minimize the need for torch cross seam
adjustment during the weld.
If the guide ring is substantially misaligned
("cocked"), it may result in rubbing the bottom
surface of the head on the pipe.
Always loosen the setscrew before unlatching the
guide ring. Mount the guide ring fairly concentrically with
the pipe OD. The arc gap control system will compensate
for variations in mounting eccentricity. Remember that the
12 mm AGC stroke must be preserved to allow automatic
torch-to-workpiece corrections both within and between
passes.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A7 TIG Orbital System 300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A7 TIG Orbital System 300 in the language / languages: English as an attachment in your email.

The manual is 4,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info